    HANNA HI 2211 Calibration Check pH/ ORP/ Temperature

    HANNA HI 2211 Calibration Check pH/ ORP/ Temperature

    Price:
    12.000.000,-
    Quantity Order:
    A properly manufactured and maintained pH electrode will retain its measuring integrity for a long time. As a result of many factors such as age, poor maintenance or improper handling, any electrodein time will lose its integrity.

    The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that theelectrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration.

    A dirty electrode or wrong calibration approach can contribute to buffer solution contamination. A contaminated buffer solution can present a major problem during calibration due to the fact that it isconsidered the only reference.

    The HI 2221 is a pH benchtop meter featuring our exclusive Calibration Check⢠diagnostics for bothpH? electrodes and buffer solutions during calibration. This instrument compares the characteristicsof the pH electrode from one calibration to the next. In the case of large variances in the electrode condition, it alerts the user that the electrode needs to be properly cleaned prior to calibration and measuring.

    The second feature is to detect if the calibration buffer solution is contaminated. After calibration, the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.

    This instrument can measure using ORP electrodes ( pH channel input) , due to itâ s capability to measure mV with a resolution up to 0.1 mV.

    This meter also features five point calibration with seven standard buffers, Automatic Temperature Compensation and GLP capabilities that allow for the storage and retrieval of all data regarding pH. With a built-in logging function, measurements are stored in non volatile memory and can be transferred to a PC through the USB port.

    Features:
    pH Calibration Checkâ¢
    On-screen electrode condition and response time
    Up to five point calibration with seven standard buffers
    Diagnostic alerts through icons
    Automatic Temperature Compensation
    GLP features
    PC interface via USB

    Includes: HI 2221-01 ( 115V) and HI 2221-02 ( 230V) and are supplied with HI 1131B pH electrode, HI 766 temperature probe, HI 76404N electrode holder, HI 70004 pH 4.01 buffer solution sachet, HI 70007pH 7.01 buffer solution sachet, HI 700661 cleaning solution sachet, HI 7071S electrolyte solution ( 30mL) , 12 VDC adapter and instructions.