Welcome to Indomonster.com
Sign In | Sign Up
Welcome to
MAJU MAPAN MANDIRI

Priority Member Indomonster Priority
14th Year
MAJU MAPAN MANDIRI
  • Sell

    FLUKE 1630 Earth Ground Clamp Meter

    FLUKE 1630 Earth Ground Clamp Meter

    Price:
    26.000.000,-
    Quantity Order:
    Earth Ground loop resistance measurements for commercial, industrial, and utility applications.

    The clamp-on ground testing technique used by the Fluke 1630 simplifies ground loop testing and enables non-intrusive leakage current measurement. The compact and rugged design makes the Fluke 1630 easy to use in small places and harsh environments, while the â display holdâ and the continuity testing with an audible alarm function ensures convenience in use. The novel technique means that earth ground loop testing and continuity testing can be completed without breaking the circuit.

    Stakeless testing system.
    The Fluke 1630 uses the Stakeless testing method, which eliminates the need to disconnect parallel ground rods and find suitable locations for placing auxiliary ground stakes. This saves time and enables users such as industrial and utility electricians, and field service electricians and contractors, to perform earth ground loop tests in locations where it is not possible to use other techniques, including inside buildings or on power pylons. With the Stakeless testing method, earth ground stakes are no longer necessary. The Fluke 1630 Earth Ground Clamp is placed around the earth ground rod or the connecting cable. A known voltage is induced by one half of the clamp and the current is measured by the other half. The tester automatically determines the ground loop resistance at this grounding connection.

    Features:
    A wide ground loop resistance range, from 0.025 O to1500 O, to satisfy all requirements
    Large jaw opening of 35 mm ( 1.38 in) for tests on ground conductors and/ or equipotential bus bars
    Measurement of ground leakage current, from 0.2 mA to 1000 mA, without needing to disconnect - ideal for system troubleshooting
    Wide ac current measurement range from 0.2 A to 30 A allows one instrument for multiple applications
    User-defined HI / LO Alarm limits, for rapid measurement evaluation
    Handy â display holdâ button for capturing readings in hard-to-reach places
    Time saving memory function automatically records and stores measured values
    Automatic self calibration ensures correct measurement every time
    Overload protection: 200 A
    Carrying case and resistance test loop included
    e 8 hours battery life ( continuous operation)

    Applications:
    Earth Ground loop testing in various installations - for example, high voltage pylons, buildings, cell phone substations, RF transmitters, etc.
    Inspection of lightning protection systems
    Leakage current measurement

    Includes:
    Rugged carrying case with shoulder strap
    Resistance test loop
    9 V battery
    User' s manual in English, French, Spanish, German, Italian, Portuguese, and Simplified Chinese


You have [3] new inquiries.
Go to Member Menu

Home - Trade List - Product List - Inquiry List - Cooperation List - Company List
Copyright © 2024 Indomonster.com. All Rights Reserved.