Products Catalog

6-in-1 Multi-Function Meter Tester EC CF TDS PH °C °F
PriceUS $59.00
Quantity Order:
OriginHong Kong SAR

Specification

Product Description:

This Six-in-One meter has been re-engineered w/ BUILT-IN RECHARGEABLE BATTERY to save you from the hassle of buying, placing & replacing button batteries. Now all you have to do is charge the Built-in Rechargeable Battery the first time you use it, then recharge it again as needed. The built-in battery can last for 4 to 5 years, with standard charging time of approximately two (2) hours.

PHT-026 device can measure up to six range.The Multi-parameter Water Quality Monitor is a versatile, high-accuracy multi-parameter instrument with reliable multi probe system and with all the functionality of a multi-parameter system. It combines the versatility of an easy-to-use, easy-to-read unit with all the functionality of a multiparameter system. Featuring simultaneously measures and displays pH, temperature (°C or °F), and EC, CF or TDS (ppm) with a single push of a button.

This combo tester is easy to use and indeed affordable plus makes it possible for non-technical and technical personnel alike to measure pH, °C, CF, EC, °F, and TDS on the spot, accurately and inexpensively throughout a variety of industries. No more switching meters to measure the pH, °C or °F and then the EC, CF or TDS of a solution.

The fast, efficient, accurate and portable, more precise measurement meets the requirements of your routine multi-measurements. And it comes with FREE pH6.864 and pH4.003 CALIBRATION SOLUTIONS and an AC ADAPTOR FOR US or UK or EUROPE or AUSTRALIA.

Simultaneously analyze 6 water quality parameters with a single submersible probe system.

Buy Now!

Features:

* With Built-in Rechargeable Battery that can last up to 5 yrs!
* Simultaneously read results
* Comes with FREE protective cap, pH Electrode, calibration screwdriver, pH6.864 and pH4.003 CALIBRATION SOLUTIONS
* Manual is provided for quick and easy installation and to best utilize PHT-026
* Has large digital Display system for easy reading
* A FREE AC POWER ADAPTOR for Australia, UK, US or Europe system is provided if you want to save the built-in battery power for later use
* The unit can be simply calibrated in one-point with a mini-screw driver and has a large digital graphic display for maximum efficiency

Specifications:

* Range
PH : 0.00~14.00PH °C : -50°C~70°C CF : 0.0~199CF

EC : 0.00~19.99EC °F : -58°F~158°F TDS : 10~19990ppm

* Resolution
PH : 0.01PH °C : 0.1°C TDS : 10ppm

EC : 0.01EC °F : 0.2°F CF : 0.1CF

* Accuracy
PH : ±0.1PH °C : 1.0°C EC, CF, TDS : ±2% F.S.

* Operating Temperature : 0°C~50°C
* Automatic Temperature Compensation (ATC) : 0°C~50
* AC Power Adaptor (for UK, US, Australia or Europe)
* Dimensions: 155mm x 86mm x 22mm
* Weight: 223g

Operating Information:

* If it will be used for the first time, the meter has to be charged first. After plugging in the AC adaptor to the meter, press ON/OFF button to turn device ON. Charge the built-in rechargeable battery for two hours before you start using PHT-026.
* Remove the PH electrode's protective cap and connect the PH electrode to the pH electrode input terminal which can be found on the leftmost part of the unit.
* Turn the meter on by pressing the "ON/OFF" switch.
* Immerse the two electrode in the solution to be tested. Stir gently and wait for the reading to stabilize.
* Press the "°C/°F" switch when choosing between °C or °F. And press the "MODE" switch when choosing EC, CF, or PPM to show precise measurement respectively.
* After using, turn off the meter. Rinse the electrode with distilled water to minimize contamination. Put back protective cap on to pH electrode.

Calibration Settings:

* PH Calibration
o Immerse the electrode in PH 6.86 standard buffer solution, and gently shake it.
o Allow the reading to stabilize. Use the mini-screw driver to tun then PH 7 calibration knob until the displays show "6.86". Rinse the electrode with distilled water, and wipe it with filter-paper.
o Immerse the electrode in pH4.01 pr pH9.18 standard buffer solution until "4.01" or "9.18" appears.
* EC, CF, ppm calibration
o Press the "MODE" switch, choose EC for operating. Immerse the meter in 12880µ s/cm (12.88EC) calibration solution.
o Allow the reading to stabilize. Use mini-screw driver turn the CAL Calibration knob until "12.88EC" appears. Rinse the electrode with distilled water, and wipe it with filter-paper.
o Immerse the meter in "1413µ s/cm (1.41EC)" calibration solution until "1413(1.41EC)" shows.
* The instrument's pH range must be re-calibrated whenever:
o The electrode has not been in used or has been in the storage for 4 or 5 months from the last calibration
o the electrode has been in used very often in a day
o the electrode has been replaced
o the utmost accuracy is required

Accessories included:

* BUILT-IN RECHARGEABLE BATTERY
* FREE pH6.864 and pH4.003 CALIBRATION SOLUTIONS
* pH Electrode
* AC Power Adaptor (for UK, US, Australia or Europe)
* Mini-Screw Driver
* User's Manual

Packaging: Foam lined Box Packaging

Warranty: 2 years warranty

Shipping: USD 24.00

Payment can be made thru the ff:
* Paypal
* Western Union
* Money Transfer

You may send your questions or clarifications to
gary@gainexpress.com

Our Customer Service representative will respond to you within the next 48 hours.

For More Product Images and Information, Visit our website
http://www.gainexpress.com
showing 188 of 191