Products Catalog

Digital AC/ DC Clamp Meter Multimeter Capacitance Ohm
Digital AC/ DC Clamp Meter Multimeter Capacitance Ohm(Aug. 20, 2010 2:52:04)
Quantity Order:

Specification

This Professional Multifunction AC/ DC Clamp Meter has both Auto & Manual Range with 5999 counts. This clamp meter measures DC and AC voltage, AC current, Resistance, Capacitance, Frequency, Diode, Continuity and ADP Measurement.

In addition to features are Backlight, MAX/ MIN Mode and Over range protection. It clamps around an electrical conductor to allow the electrical current in the conductor to be measured, without having physical contact with it, or to disconnect the wiring through which the current is flowing.

It complies with all essential health and safety requirements set out in European Community Directives. It also meet internationally proven safety standards such as IEC1010-1, IEC1010-2-032, concerning electrical measuring instruments with double insulation overvoltage category 1000V CAT II 600V CAT III and pollution degree 2.

Order Today!

Features: offers the highest combination of features, functions and safety with superior performance

* Professional Multifunction AC/ DC Clamp Meter
* Test Functions DCV, ACV, ACA, Resistance, Continuity, Diode, Capacitance, Frequency, and ADP Measurement
* Function keys: Data hold, MIN/ MAX and Backlight
* International Standards: CE, IEC1010-1, IEC1010-2-032, CATII 1000V, CATIII 600V, EMC
* Reliable and accurate measured results
* · 40mm maximum conductor diameter
* Ergonomic grip with bigger jaw opening and larger conductor size
* Bigger LCD screen with higher maximum reading
* Overload Protection
* Impedance in circuit is below 40O with buzzer alarm
* Auto power off and low battery indication
* Auto and Manual Ranging
* Safety Guard and secured jacks
* Double insulated
* Design in accordance with Electromagnetic Compatibility ( 89/ 336/ EEC) & Low Voltage ( 73/ 23/ EEC as amended by CE Marking ( 93/ 68/ EEC)
* Includes heavy-duty test leads and batteries
* Brand new

Specifications:

* Accuracy:
± % of reading ± number of least significant digits at 18~ 28 ° C, with relative humidity up to 75 % . All specifications assume less than 1 year since calibration. Temperature coefficient: 0.1 x specified accuracy / ° C

* General Specifications:
* Maximum Voltage: 1000V CATII 600V CATIII
* Altitude: 2000m
* Display:
* LCD 5999 counts
* Update 2 ~ 3 per second
* Ranging Method: Auto/ manual Range Mode
* Polarity Indication: " -" display for negative polarity
* Over Range Indication: LCD will display " OL"
* Low Battery: icon will appears on LCD
* Jaw Capability: 40mm, Max conductor size
* Power: 3 x 1.5V AAA Batteries
* Operating Temperature: 5 ~ 35° C
* Storage Temperature: -10 ~ 50° C
* Dimension: approx. 225 ( L) x 86 ( W) x 32 ( D) mm ( 8.86' x 3.39' x 1.26' inch)
* Weight: approx. 330g

* Electrical Specifications:

DC Voltage
Range: 6 V
Resolution: 1 mV
Accuracy: ± ( 0.8 % of reading + 5 digits)

Range: 60 V
Resolution: 10 mV
Accuracy: ± ( 0.8 % of reading + 5 digits)

Range: 600 V
Resolution: .1 V
Accuracy: ± ( 0.8 % of reading + 5 digits)

Range: 1000 V
Resolution: * 1 V
Accuracy: ± ( 1.0 % of reading + 5 digits)

- Input Impedance : 10MO ( ohm)
- Overload Protection: 1000V DC or 700V AC RMS

AC Voltage
Range: 6 V
Resolution: 1 mV
Accuracy: ± ( 1.2 % of reading + 5 digits)

Range: 60 V
Resolution: 10 mV
Accuracy: ± ( 1.2 % of reading + 5 digits)

Range: 600 V
Resolution: 0.1 V
Accuracy: ± ( 1.2 % of reading + 5 digits)

Range : 750 V
Resolution: 1 V
Accuracy: ± ( 1.5 % of reading + 8 digits)

- Input Impedance : 10MO ( ohm)
- Frequency Range: 40~ 400Hz
- Overload Protection: 1000V DC or 700V AC RMS

AC Current

Range: 600 A
Resolution: 0.1 A
Accuracy: ± ( 2.5 % of reading + 5 digits)

Range: 1000 A
Resolution: 1 A
Accuracy: ± ( 3.0 % of reading + 5 digits)

- Overload Protection: 120 % ranges for 60 seconds max.
- Frequency Range: 50~ 60Hz

Resistance
Range: 600O
Resolution: 0.1O
Accuracy: ± ( 1.0 % of reading + 3 digits)

Range: 6kO
Resolution: 1O
Accuracy: ± ( 1.0 % of reading + 3 digits)

Range: 60kO
Resolution: 10O
Accuracy: ± ( 1.0 % of reading + 3 digits)

Range: 600kO
Resolution: 0.1kO
Accuracy: ± ( 1.0 % of reading + 3 digits)

Range: 6MO
Resolution: 1kO
Accuracy: ± ( 1.0 % of reading + 3 digits)

Range: 60MO
Resolution: 10kO
Accuracy: ± ( 5.0 % of reading + 8 digits)

- Overload Protection: 250V DC or RMS, AC for all ranges

Capacitance

Range: 600 nF
Resolution: 0.1 nF
Accuracy: ± ( 5.0 % of reading + 8 digits)

Range: 6 µ F
Resolution: 1 nF
Accuracy: ± ( 4.0 % of reading + 5 digits)

Range: 60 µ F
Resolution: 10 nF
Accuracy: ± ( 4.0 % of reading + 5 digits)

Range: 600µ F
Resolution: 0.1 µ F
Accuracy: ± ( 4.0 % of reading + 5 digits)

Range: 1000 µ F
Resolution: 1 µ F
Accuracy: ± ( 5.0 % of reading + 8 digits)
- Overload Protection: 250V DC or rms, AC for all ranges

ADP
Range: 600 mV
Resolution: 0.1 mV
Accuracy: ± ( 3.0 % of reading + 5 digits)

Frequency
Range: 40 Hz
Resolution: 1 Hz
Accuracy: ± ( 0.1 % of reading + 1 digits)

Range: 600 Hz
Resolution: 1 Hz
Accuracy: ± ( 0.1 % of reading + 1 digits)

Range: 6 kHz
Resolution: 1 Hz
Accuracy: ± ( 0.1 % of reading + 1 digits)

Range: 60 kHz
Resolution: 10 Hz
Accuracy: ± ( 0.1 % of reading + 1 digits)

Range: 100 kHz
Resolution: 0.1 kHz
Accuracy: ± ( 0.1 % of reading + 1 digits)
- Measurement Range: 1V to 10V RMS, 40Hz ~ 100kHz

Audible Continuity and Diode Test
Range: Audible Continuity
Description: If continuity exists ( about less than 40O) , built-in buzzer will sound

Range: Diode
Description: Show the approx. Forward Voltage of the diode

Accessories included:

* FREE 3 x 1.5V AAA Battery
* Test Leads
* Intruction Manual
* FREE protective zippered carrying pouch
* Standard packaging box
* Warranty: 2 years warranty

All our products are manufactured under the strict quality control guidelines established by EN ISO9001-2000 Standards
showing 55 of 191