Products Catalog

BATTERY REFRACTOMETER ° C Antifreeze glycol + LED light
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
OriginHong Kong SAR

Specification

Product Description:

A battery refractometer is designed for testing the refractive index or concentration of battery fluids, antifreeze liquid and cleaning fluids that works on the critical angle principle. They utilize lenses and prisms to project a shadow line onto a small glass reticle inside the instrument, which is then viewed by the user through a magnifying eyepiece.

In use, a sample is sandwiched between a measuring prism and a daylight plate. The reading is taken when a shadow line crosses the scale from the shadow line formed between the illuminated area and the dark area then a shadow line crosses the scale. Because refractive index is very temperature dependent, the ZGRA-200ATC Handheld Refractometer embedded a bi-metallic strip inside the rugged casing to achieve automatic temperature compensation. With the indication of the percentage you may know which temperature the fluid will be frozen for both propylene glycol and ethylene glycol. It can also be used for checking the strength of electrolyte solution batteries. And now that this new refractometer has its own light source you can still gauge concentration even in the dark, no other illumination is needed.

The Handheld Battery Refractometer offers a great value for your money because of its BUILT-IN LED. Not only is it quick and easy to use and calibrate but it also assures you that the determined concentration is reliable and accurate. Plus, ZGRA-200ATC can also measure the concentration of ethylene glycol or propylene glycol in antifreeze liquids. No need to convert to other units of temperature, the ZGRA-200ATC comes in Celsius or Centigrade.

Choose more value for your money with the ZGRA-200ATC Handheld Battery Refractometer.

Buy Now!

Features:

* Assures high quality and accurate testing results
* Power requires three ( 3) 1.5V button type batteries
* Batteries last for more than 100 hours
* With built-in white LED light source
* With ATC Compensation range from 10° C to 30° C
* Operations manual is provided for easier and convenient usage of the end-user.

Specification:

# Measuring Range:
Ethylene Glycol: -60° C ~ 0° C
Propylene Glycol: -50° C ~ 0° C
Battery: 1.100-1.400sg
# Minimum Division:
Ethylene Glycol: 5° C
Propylene Glycol: 5° C
Battery: 0.01sg
# Accuracy:
Ethylene Glycol: ± 5° C
Propylene Glycol: ± 5° C
Battery: ± 0.01sg

# ATC Compensation Range: 10° C~ 30° C
# Power Supply: 3 x 1.5V ( Button Batteries)
# Calibration: Manual with the mini-screw driver
# Dimension: 35mm x 35mm x 146mm
# Light source: White LED

Operating Information:

* Aim the front end of the refractometer to the direction of bright light source or just need to use the built-in light source, and adjust the eyepiece ( focus adjustment) until the reticle scale can be seen clearly.

* Adjustment of null ( also called calibration) : Open the daylight plate. Drop one or two drops of distilled water or R.O water on the prism. Close the daylight plate and press it lightly so the water spreads across the entire surface of the prism without air bubbles or dry spots. Allow the sample to remain on the prism for approximately 30 seconds. Then adjust the calibration screw to make the white and blue boundary coincide with the null line. Adjustment of refractometer should be made under the condition of 20° C environmental temperature. The refractometer should be adjusted to null before you leave it in the storage.

* Open the daylight plate and clean the surface of the prism with soft cotton cloth. Drop 1-2 drops of solution to be measured. Close the daylight plate. Press it lightly so the water spreads across the entire surface of the prism without air bubbles or dry spots. Allow the specimen to remain on the prism for approximately 30 seconds. The reading is the ( Salinity or the other characters we want to know) of the measured solution.

* After measurement, clean away the measured solution on the surface of the prism and daylight plate with moist cotton cloth. After drying, it should be stored properly.

Maintenance:

* Recalibrate occasionally to ensure and maintain the testing accuracy.

* Adjustment of null: Liquid and specimen should be under the same temperature. If the temperature varies greatly, the null point should be adjusted once per every 30 minutes.

* After usage, don' t use water to wash the instrument, so as to prevent moisture from entering the instrument.

* As it is a specialized precision optical instrument, you should handle it gently and take good care of it. Don' t touch and scratch the optical surfaces. It should be kept in a dry environment, with clean and non-corrosive air, so as to prevent the surface from turning moldy and foggy. Please avoid strong shock during transportation.

* If the consumers use the instrument in accordance with the mentioned method of usage, it can be guaranteed that the instrument will be operational for quite a period of time, with its optical performance unchanged.

Accessories included:

* Operations Manual
* 3 x 1.5V button type batteries
* Mini-screw driver
* Pipettes + 10 pieces FREE PIPETTES

Packaging: Sturdy cushioned traveling box

Warranty: 2 years warranty

Shipping: USD 9.80

Payment can be made thru the ff:
* Paypal
* Western Union
* Money Transfer

You may send your questions or clarifications to
gary@ gainexpress.com

Our Customer Service representative will respond to you within the next 48 hours.

For More Product Images and Information, Visit our website
http: / / www.gainexpress.com
showing 149 of 191