Welcome to
WIJAYAMAS TEKNINDO CV

Free Member
WIJAYAMAS TEKNINDO CV
Indonesia
  • Products Catalog

    PA9Plus Power Analyser

    Price:
    Hub :021- 32375508
    Quantity Order:
    Origin:
    United States

    Specification :

    SPECIFICATIONS
    Specifications are at 25° C ( 77° F) .
    Applicable Measurement Standards
    EN50160, IEEE1159, IEEE519, IEC61000-4-15, IEC 61000-4-30
    Voltage ( 4 Differential Input Channels)
    Voltage Range
    Three high-voltage channels autoranging between 20 to 600 V
    ac/ V dc scales and one low-voltage channel autoranging between
    0.1 to 350 V ac or V dc, true RMS through the 63rd harmonic
    Low Voltage Channel Accuracy
    Range Accuracy
    0 V to 4.9 V > .5% of reading
    5.0 V to 9.9 V Within .5% of reading
    10 V to 14.9 V Within .3% of reading
    15 V to 340.0 V Within .2% of reading
    340 V to 350 V > .3% of reading
    High Voltage Channel Accuracy
    Range Accuracy
    10 V to 30 V > .4% of reading
    30 V to 70 V Within .4% of reading
    70 V to 350 V Withing .25% of reading
    350 V to 600 V Within .4% of reading
    Crest Factor
    Voltage
    Limited to 1500 V peak ( not including impulses)
    for high voltage channels
    Limited to 500 V peak for low voltage channel
    Current: 1.4 of full scale at peak input
    Current ( 5 channels)
    Current Resolution: 0.1% of full scale
    Current Accuracy: ± 0.25% of reading ± 0.5% of range,
    plus the current probe accuracy
    Current channels receive 0 to 1 Volt RMS from probes
    Current channel voltage 0.25% of reading, ± 5 mV
    Voltage/ Current Connectors
    V = 4 color coded pairs of safety banana jacks; I = 5 Amp
    miniature circular connector; power provided for flexible CTs
    Frequency
    Fundamental Frequency: 20 Hz to 70 Hz autoranging via phase
    lock loop
    Frequency Response: dc to the 63rd harmonic with low pass
    anti-aliasing filter
    Frequency Resolution: 0.01 Hz
    Frequency Accuracy: 0.01 Hz at 60 Hz
    Phase Angle Error
    ± 1° referenced to first voltage channel at 60 Hz
    Sample Rate
    20-70 Hz: 256 samples/ cycle
    Voltage and current for each phase are sampled simultaneously
    Channel to Channel Isolation
    6000 Volts peak on voltage channels
    Control
    Silicon rubber keypad, four cursor controls with select switch and
    six buttons ( home, back, default, record, cursor select, power on)
    Time
    Real Time Clock: internally maintained and updatable via
    computer
    Time Accuracy: Better than ± 0.005%
    Power Supply
    Selectable between either A-phase voltage input or nonrecording
    IEC-style power input. A-phase voltage powering input
    requirement 90-600 V ac or 110-600 V dc. IEC power input
    requirement 90-250 V ac.
    Battery
    12 V backup battery included for ride-through of outages to 15
    minutes and local data analysis without a power connection
    Battery Recharge Time: 16 hours
    Run Through Time: If recording, 15 minutes when instrument
    power input falls below minimum voltage level listed above. After
    15 minutes, automatically resume recording on restoration of
    minimum input power using correct date and time.
    Data Retention: 10 years via nonvolatile, solid-state internal flash
    memory
    Environmental
    Operating Temperature: -20º to + 50º C ( -4º to 122º F) ambient
    temperature
    Humidity: Meets NEMA 4X, rain resistant; 90% non-condensing,
    not watertight
    Case: NEMA 4X, ( IP54) , nonconductive, corrosion resistant, rain
    resistant, not submersible
    Communications
    RS-232: 3 wire, 115 KBPS, Standard DB9 connector
    External RS-232 ( Optional) : For serial port access to instrument
    data while front lid remains closed
    Modem ( Optional) : internal modem
    Display
    Type: Backlit, 5 in. x 1.5 in., 240 x 64 pixels graphic LCD
    Operating Temperature: 0º to + 50º C ( 32º to 122º F)
    Optional Customer Defined Start-up Screen Text
    The factory presets two lines of the start-up/ about screen to
    customer specific data ( i.e. owner contact information, lost/ found
    message, etc.) . Each line may contain up to 40 characters of text.
    Memory Options
    Standard: 12 megabytes internal flash
    Optional: Instrument slot and adapter on front panel of PA9Plus
    for inserting and removing compact flash memory cards.
    Physical
    Size: Portable — 330 x 254 x 152 mm ( 13 x 10 x 6 in.)
    Weight: 5.6 kg ( 15 lbs)