    SPECIFICATION
    Insulation
    Nominal test voltages
    MIT40X 10 V to 100 V variable ( 1 V increments)
    Insulation resistance range ( at maximum test voltage)
    MIT40X 20 G½
    Range Full Scale Accuracy
    All ranges ± 2% ± 2 digits up to 100 M½ .
    All ranges ± 2% ± 2 digits up to 100 M½ .
    Then:
    1000 volts ± 3% ± 2 digits ± 0.2% per G½
    500 volts. ± 3% ± 2 digits ± 0.4% per G½
    250 volts. ± 3% ± 2 digits ± 0.8% per G½
    100 volts. ± 3% ± 2 digits ± 2.0% per G½
    50 volts. ± 3% ± 2 digits ± 4.0% per G½
    10 volts ± 3% ± 2 digits ± 2.0% per 100 M½
    Analogue range: 1 G½ full scale
    Short Circuit Current: 2 mA + 0% -50%
    Terminal voltage: -0% + 20% ± 1 V
    MIT40X ± 1 V
    Test Current on load:
    1 mA at min. pass value of insulation specified in BS7671, HD384
    and IEC364, 2 mA max.
    EN61557 Operating range: 0, 10 M½ to 1, 00 G½
    Leakage current range 10 ¼ A 2000 ¼ A
    Leakage current: 10% ± 3 digits
    Voltage display: 3% ± 3 digits ± 0.5% of rated
    voltage
    Polarisation Index ( PI) : 10 min / 1minute ratio
    Dielectric Absorption Ratio ( DAR) : 60 sec / 30 sec ratio
    Notes:
    ( 1) All ranges measure from 0, 00 M½ upwards.
    ( 2) Above specifications only apply when high quality silicone leads
    are being used.
    Continuity
    Measurement: 0, 01 ½ to 99, 9 ½ ( 0 to 100 ½ on
    analogue scale)
    Accuracy: ± 2% ± 2 digits ( 0 to 100 ½ )
    Open circuit voltage: 5 V ± 1 V
    Test current: 205 mA ( ± 5 mA)
    ( 0.01 ½ to 9.99 ½ )
    20mA ( ± 1 mA )
    ( 10.0 ½ to 99.9 ½ )
    Zero offset at probe tips: 0, 10 ½ typical
    Lead resistance zeroing: Up to 9.99 ½
    Buzzer: Variable limit 1 ½ , 2 ½ , 5 ½ ,
    10 ½ , 20 ½
    Resistance
    Measurement: 0.01 k½ to 1000 k½ ( 0 to 1 M½
    on analogue scale)
    Accuracy: ± 3% ± 2 digits up to 50 k½
    then ± 5% ± 2 digits
    Open circuit voltage: 5 V ± 1 V
    Short circuit current: 1.5 mA ± 0.2 mA
    Voltage range
    0 to 600 V d.c. ± 2% ± 2 digits
    10 mV to 600 V TRMS sinusoidal ( 40 to 400 Hz) ± 2% ± 2 digits
    0 to 1000 V on Analogue scale
    Unspecified input level 0 - 10 mV ( 40 to 400 Hz)
    For non-sinusoidal waveforms additional specification
    apply:
    ± 3% ± 2 digits 101 mV to 600 V TRMS and ± 8% ± 2 digits 10 mV to
    100 mV TRMS
    Default Voltmeter: Operates at > 25 V a.c. or d.c.
    on any range except OFF
    Frequency: 40-450 Hz ( 40 Hz - 99.9 Hz)
    ± 0.5% ± 1 digit ( 100 Hz to
    450 Hz)
    Capacitance measurement
    MIT420, MIT430
    Measurement range: 100 pF to 10 ¼ F
    Accuracy: ± 5.0% ± 2 digits
    Distance by capacitance:
    MIT420, MIT430
    Arithmetic conversion from capacitance measurement on
    Default capacitance measurement: 50nF/ km
    Capacitance range: 40 nF/ km to 60 nF/ km
    Result storage
    Capacity: > 1000 test results
    Download: Bluetooth wireless
    Bluetooth Class: Class II
    Range: up to 10 m
    Power Supply:
    5 x 1, 5 V cells type IEC LR6 ( AA, MN1500, HP7, AM3 R6HP) Alkaline
    NiMH rechargeable cells may be used.
    Battery life: 2200 insulation tests with duty cycle of 5 sec ON / 55
    sec OFF @ 1000 V into 1 M½
    Dimensions
    Instrument: 220 x 92 x 50 mm ( 8.66 in. x 3.63 in. x 1.97 in.)
    Instrument + case: 456 x 178 x 89 mm ( 18 in. x 7 in. x 3.5 in.)
    Weight
    Instrument only: 590 gms, 775 gms with boot ( 20.73 oz.
    27.22 oz.)
    Instrument plus case: 1.75kg ( 3.86 lb)