    Specifications
    Data Log Functions
    Measure functions: Voltage, current, resistance, frequency, temperature, pressure
    Reading rate: 1, 2, 5, 10, 20, 30, or 60 readings/ minute
    Maximum record length: 8000 readings ( 7980 for 30 or 60 readings/ minute)
    Ramp Functions
    Source functions: Voltage, current, resistance, frequency, temperature
    Rate: 4 steps/ second
    Trip detect: Continuity or voltage ( continuity detection not available when sourcing current)
    Loop Power Function
    Voltage: Selectable, 24 V or 28 V
    Accuracy: 5%
    Maximum current: 22 mA, short circuit protected
    Maximum input voltage: 30 V DC
    Step Functions
    Source Functions Voltage, current, resistance, frequency, temperature
    Manual Step Selectable step, change with arrow buttons
    Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat
    Environmental Specifications
    Operating Temperature
    -10° C to + 50° C
    -20° C to + 50° C *
    Storage Temperature
    -20° C to + 60° C
    Dust/ water resistance
    Meets IP52, IEC 529
    Operating Altitude
    2800 m
    Note
    * Except frequency and AC
    Safety Specifications
    Agency Approvals
    CAN/ CSA C22.2 No 1010.1-92, ASNI/ ISA S82.01-1994, UL3111, and EN610-1: 1993
    Mechanical & General Specifications
    Size
    130 x 236 x 61 mm
    Weight
    1.4 kg
    Batteries
    NiCd: 7.2V, 1.7 Ah
    Battery Life
    ~ 8 hours typical
    Battery Replacement
    Via snap-shut door without opening calibrator; no tools required
    Side port connections
    Pressure module connector
    RS-232 connector for PC interface cable
    Connection for optional battery eliminator
    Data storage capacity
    1 week of calibration results
    90 day specifications
    The standard specification intervals for the 743B is 1 and 2 years.
    Typical 90 day measurement and source accuracy can be estimated by
    dividing the one year " % of reading" or " % of output" specifications by 2.
    Floor specifications, expressed as " % of full scale" or
    " counts" or " ohms" remain constant