    Fluke 1507/ 1503 Insulation Resistance Testers

    Fluke 1507/ 1503 Insulation Resistance Testers

    Price:
    Hub 021 - 32375508
    Quantity Order:
    Origin:
    United States

    Specification :

    AC/ DC Voltage Measurement
    Accuracy
    Range 600.0 V
    Resolution 0.1 V
    50 Hz to 400 Hz ± ( % of Rdg + Digits) ± ( 2 % + 3)
    Input impedance
    3 M© ( nominal) , 60 dB at dc, 50 or 60 Hz
    Overload Protection
    600 V rms or dc
    Earth bond resistance measurement
    Range/ Resolution
    20.00 © 0.01 ©
    200.0 © 0.1 ©
    2000 © 1.0 ©
    20.00 k© 0.01 k©
    Accuracy
    ± ( 1.5 % + 3)
    Overload Protection
    2 V rms or dc
    Open Circuit Test Voltage
    > 4.0 V, 200.0 mA
    Insulation specifications
    Measurement Range
    1507: 0.01 M© to 10 G©
    1503: 0.01 M© to 2000 M©
    Test voltage
    1507: 50 V, 100 V, 250 V, 500 V, 1000 V
    1503: 500 V, 1000V
    Test Voltage Accuracy
    + 20 % , - 0 %
    Short circuit current
    1 mA nominal
    Auto Discharge
    Discharge time 30 V prior to initialization of test
    Maximum Capacitive Load
    Operable with up to 1 µ F load
    Measure Accuracy:
    50 V: ± ( 3 % + 5)
    100 V: ± ( 3 % + 5)
    250 V: ± ( 1.5 % + 5)
    500 V: ± ( 1.5 % + 5)
    1000 V: ± ( 1.5 % + 5) to 2000 M© , ± ( 10 % + 3) above 2000 M©
    General Specifications
    Maximum voltage applied to any terminal:
    600 V ac rms or dc
    Storage Temperature
    -40 ° C to 60 ° C ( -40 ° F to 140 ° F)
    Operating Temperature
    -20 ° C to 55 ° C ( -4 ° F to 131 ° F)
    Temperature Coefficient
    0.05 x ( specified accuracy) per ° C for temperatures 28 ° C ( 82 ° F)
    Relative Humidity
    0 % to 95 % @ 10 ° C to 30 ° C ( 50 ° F to 86 ° F)
    0 % to 75 % @ 30 ° C to 40 ° C ( 86 ° F to 104 ° F)
    0 % to 40 % @ 40 ° C to 55 ° C ( 104 ° F to 131 ° F)
    Vibration
    Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
    Shock
    1 meter drop per IEC 61010-1 2nd Edition ( 1 meter drop test, six sides, oak floor)
    Electromagnetic compatibility:
    In an RF field of 3 V/ M, accuracy = specified accuracy ( EN 61326-1: 1997)
    Safety
    Complies with ANSI/ ISA 82.02.01 ( 61010-1) 2004, CAN/ CSA-C22.2 NO. 61010-1-04, and IEC/ EN 61010-1 2nd Edition for measurement category IV 600 V ( CAT IV)
    Certifications:
    CSA per standard CSA/ CAN C22.2 No. 61010.1-04; TUV per standard IEC/ EN 61010-1 2nd Edition
    Batteries
    Four AA batteries ( NEDA 15A or IEC LR6)
    Battery Life
    Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M© with a duty cycle of 5 seconds on and 25 seconds off.
    Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 © with a duty cycle of 5 seconds on and 25 seconds off.
    Size
    5.0 cm H x 10.0 cm W x 20.3 cm L ( 1.97 in H x 3.94 in W x 8.00 in L)
    Weight
    550 g ( 1.2 lb)
    IP Rating
    IP40
    Altitude
    Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V
    Non-operating ( storage) : 12, 000 m
    Over-range capability:
    110 % of range
    Included accessories:
    TL224 Test Leads, TP74 Test Probes, clips PN 1958654 ( red) and PN 1958646 ( black) , holster and remote probe