Welcome to
Beijing Safe Heart Technology Ltd.

Free Member
Beijing Safe Heart Technology Ltd.
Beijing Safe Heart Technology Ltd.
China
  • Products Catalog

    ICU Ventilator

    ICU Ventilator

    Price:
    will be sent you by email
    Quantity Order:
    Origin:
    China
    Payment Method:
    Telegraphic Transfer (T/T)
    Pack. & Delivery:
    as per your requirement

    Specification :

    Feature

    Advanced ICU Ventilator with high-technology
    Pneumatically driven and electronically controlled
    12.13TFT touch screen with advanced technology
    Multi-ventilation modes better for patient monitoring
    Suitable for pediatric and adult with wide volume
    Multi- alarms setting for safety guarantee
    Built-in battery for long time assistance
    Loop functions of P-V & F-V
    Special nebulization function
    Interface for RS232 , USB and VGA

    Technical Specification:
    Specification:

    Volume Controlled ( VCV) , Assist/ Control
    Pressure Controlled ( PCV) , Assist/ Control
    Synchronized Intermittent Mandatory Ventilation ( SIMV)
    Volume-controlled breaths ( V-SIMV)
    Pressure-controlled breaths ( P-SIMV)
    Pressure Support Ventilation ( PSV)
    Spontaneous Ventilation ( SPONT)
    Continuous Positive Airway Pressure ( CPAP)
    Bi-level Positive Airway Pressure ( BIPAP)
    Combined: VCV+ SIGH, SIMV( VCV) + PSV, SIMV( PCV) + PSV

    Parameter:

    Tidal volume: 20~ 1500ml
    Respiratory rate: 1~ 100bpm
    Inspiration time: 0.1~ 12s
    Inspiration pause time: 0~ 4s
    FiO2: 21^ 100% , OFF
    Trigger sensitivity: Pressure( -2~ 0kPa, above PEEP)
    Flow ( 0.5~ 20LPM, with base flow)
    PEEP: 0~ 5kPa
    Psupport: 0~ 7kPa
    Pcontrol: 0.5~ 7kPa
    Phigh: 0.5~ 7kPa
    Plow: 0~ 5kPa
    E-sense ( Option) : 10% ~ 60%
    100% O2 ( Option) : 2min
    Inspiration hold ( Option) : Yes
    Expiratory hold ( Option) : Yes
    Manual inspiration ( Option) : Yes
    Freeze( Option) : Yes
    Nebulizer( Option) : 30 minutes
    Key lock: Yes
    EtCO2 .Pulse Rate.SPO2.FiCO2

    Monitoring:

    Pressure values: Paw, Pplat, Pmean, PEEP
    Volume/ Flow values: VTi, VTe, MV, MVspont
    Time Values: Ftotal, Fspont, I: E
    Oxygen monitoring: With O2 sensor ( option) , without O2 sensor
    Real time curves: Pressure-Time, Flow-Time, Volume-Time, Pressure-Volume Loop, Flow-Volume Loop, SPO2-Time, EtCO2-Time.
    Respiratory mechanics, Dynamic and static compliance, Resistance, Auto PEEP

    Alarm:

    MVhigh, MVlow, Circuit disconnected, Paw high, Paw low, Airway Pressure High, VTe high, Pspont high, Tapnea, FiO2 low, Power Supply Failure, Nebulizer on, Battery Low, Battery Exhausted, Air Supply Down, O2 Supply Down, Air& O2 Supply Down

    Technical Data:

    Screen: 12.13TFT touch screen
    Gas supply: O2, Air ( 0.28~ 0.6MPa)
    Power supply: AC110~ 240V, 50Hz/ 60Hz, 80VA
    Maximum security pressure: 8kPa
    Compliance: 4ml/ 100Pa
    Noise: 65dB( A)
    Communication interfaces: RS232, VGA port

    Environment requirement:

    Temperature: 5 ~ 40 ( Operation)
    -10 ~ 55 ( Storage)
    Relative humidity: d80% , non-condensing ( Operation)
    d93% , non-condensing ( Storage)
    Atmospheric pressure: 86~ 106kPa ( Operation)
    86~ 106kPa ( Storage)
    Atmospheric operation: 500~ 800mmHg/ 3565~ -440m( Operation)
    375~ 800mmHg/ 5860~ -400m( Storage)