    SHM-3012

    Ã 12.1â active matrix TFT LCD Screen
    Ã ECG, SpO2, NIBP, RESP, TEMP, HR and PR
    Ã Optional Dual-IBP, EtCO2, Built-in thermal recorder, Built-in battery, Pacemaker pulse rejection
    Ã PVC analysis
    Ã Defibrillator overload protection
    Ã Electrosurgery protection
    Ã Pacemaker detector
    Ã HRV and 13 kinds of Arrhythmia analysis S-T segment analysis
    Ã 300 seconds ECG waveform review
    Ã Maximum 72-hour graphic and tabular trends of all parameters and 72-hour data records, 100 items alarm event records
    Ã Adjustable 3-level audible and visual alarm
    Ã Application from adult to neonate
    Ã Support wired compatible with Safeheart central monitoring system

    Technical Specifications

    Power: 100~ 250V AC, 50/ 60 Hz

    Battery:

    Lead-acid recharge battery
    Working more than 100 minutes when full charge
    About 5 minutes working after first low-power alarm
    Battery charge time is not more than 12 hours

    ECG

    Lead mode: 3-lead or 5-lead
    Lead selection: I, II, III, AVR, AVL, AVF, V
    Gain: x 250, x 500, x 1000, x 2000
    HR range: Adult: 15 ~ 300 bpm
    Pediatric/ neonate: 15 ~ 350 bpm
    Accuracy: ± 1% or ± 1bpm, which is greater
    Resolution: 1 bpm
    Sensitivity: > 200 uV
    Input resistance: > 5M Ohm
    CMRR: Diagnosis mode: > 90 dB
    Monitor mode: > 100 dB
    Operation mode: > 100 dB
    Electrode offset potential: ± 300mV
    Pacemaker Pulse Detecting: YES
    ECG signal range: ± 8 mV
    S-T detection: YES,
    Arrhythmia analysis: YES
    Alarm: YES, audible and visual alarm, alarm events recallable

    RESP

    Technique: Trans-thoracic impedance ( RA-LL or LA-LL)
    Measurement range: Adult: 6 ~ 120 BrPM
    Pediatric/ neonate: 6 ~ 150 BrPM
    Resolution: 1 BrPM
    Accuracy: ± 2 BrPM
    Apnea alarm: 10 ~ 40 s

    SpO2

    Measurement range: 0 ~ 100%
    Resolution: 1%
    Accuracy: 70 ~ 100% : ± 2%
    0 ~ 69% : unspecified

    Pulse Rate

    Measurement range: 0 ~ 254 bpm
    Resolution: 1 bpm
    Accuracy: ± 2 bpm

    TEMP

    Transducer: YSI/ CYF series
    Channel: dual-channel
    Measurement range: 0 ~ 50
    Resolution: 0.1
    Accuracy: ± 0.1

    NIBP

    Measurement mode: Manual/ auto pulse wave oscillation
    Measurement interval time: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480min
    Continuous measuring time: 5 min
    Measurement range:
    Adult:
    Systolic: 40 ~ 270 mmHg
    Diastolic: 10 ~ 215 mmHg
    Mean arterial: 20 ~ 235 mmHg
    Pediatric:
    Systolic: 40 ~ 200 mmHg
    Diastolic: 10 ~ 150 mmHg
    Mean arterial: 20 ~ 165 mmHg
    Neonate:
    Systolic: 40 ~ 135 mmHg
    Diastolic: 10 ~ 100 mmHg
    Mean arterial: 20 ~ 110 mmHg
    Accuracy: the mean error shall be less than ± 5 mmHg, the standard deviation shall be less than ± 8 mmHg
    Overvoltage protection: YES

    Recorder( optional)

    Width: 48mm
    Speed: 25mm/ S
    Wave: 2
    Type: 8s, 16s, 32s real-time record

    IBP( optional)
    Channel: 2 channels
    Transducer sites: ART, PA, CVP, RAP, LAP, ICP, P1, P2
    Measuring and alarm range
    ART: 0 ~ 300 mmHg
    PA: -6 ~ 120 mmHg
    CVP/ RAP/ LAP/ ICP: -10 ~ 40 mmHg
    P1/ P2: -10 ~ 300 mmHg
    Press Sensor Sensitivity: 5 uV/ V/ mmHg
    Resolution: 1 mmHg
    Accuracy: ± 2% or ± 1mmHg, which is greater
    Actualization interval: about 1s

    EtCO2( optional)
    Measurement Mode: Side-stream or Mainstream
    Measurement range: 0% ~ 13%
    Resolution: 1 mmHg
    Accuracy: 2 mmHg @