Product details: Model ZLT-LJ1: The ZLT Plug torque tester is for compliance is checked by engaging the device, as during intended use, with the socket-outlet of a test apparatus as shown in IEC60065 Figure 11. A device provided with pins intended to be introduced into fixed socket-outlets shall not impose undue strain on these socket-outlets. The balancing arm of the test apparatus pivots about a horizontal axis through the centre lines of the contact tubes of the socket-outlet at a distance of 8 mm behind the engagement face of the socket-outlet. With the device not in engagement, the balancing arm is in equilibrium, the engagement face of the socket-outlet being in the vertical position. After the device has been engaged, the torque to be applied to the socket-outlet to maintain its engagement face in the vertical plane is determined by the position of a weight on the balancing arm. The torque shall not exceed 0, 25 Nm. . Load: 0.5N* 2/ 1.25N* 1/ 0.25N* 1 Plug: UL plug* 1, Australia plug* 1, all-purpose plug* 1 Conforms to standard: IEC60884, VDE0620, IEC60598, IEC60065Fig11