Free Member 
Language :
CV. ANDALAN PRIMA SEJAHTERA
CV. ANDALAN PRIMA SEJAHTERA
http://indomonster.com/cv_aps/
CV. ANDALAN PRIMA SEJAHTERA
Contact Information
Name:
Mrs. REGINA / VANNY / VITHA [Director/CEO/General Manager]
E-mail:
Homepage:
Instant Messaging:
Y!: andalan1974@yahoo.com 
Phone Number:
Phone number of Mrs. REGINA / VANNY / VITHA at JAKARTA
Mobile Number:
Mobile number of Mrs. REGINA / VANNY / VITHA at JAKARTA
Fax Number:
Fax number of Mrs. REGINA / VANNY / VITHA at JAKARTA
Address:
Jl. muchtar tabrani, Perum Bintang Metropol Blok A7/16 Bekasi
JAKARTA, Jakarta
Indonesia
Average User Review

There is no review for this company

Write a review

Products Catalog

KYORITSU 6010B
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
Pack. & Delivery1 unit
OriginJapan

Specification

⢠Continuity:
20/200©
200mA Test Current
⢠Insulation:
500/1000V, 20/200M©
1mA Rated Test Current
⢠Loop Impedance:
20/2000©
15mA Test Current at 2000© (No RCD Trip)
⢠RCD:
10/30/100/300/500mA
x1/2, x1, Fast Trip(40ms), DC, Auto Ramp
⢠Test of a large kind of RCD's:
Standard, Selective, AC and A
(DC sensitive breakers)
⢠Uc(Contact Voltage): 100V
⢠Designed to IEC 61010-1, IEC 61557
⢠Data Memory:300 measured results
⢠The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.

Continuity Testing :
- Measuring Range : 20/200© (Auto-Ranging)
- Open Circuit Voltage : > 6V
- Short Circuit Current : > 200mA
- Accuracy : ±(3%rdg + 3dgt)
Insulation Resistance Testing :
- Measuring Range : 20/200M© (Auto-Ranging)
- Test Voltage : 500/1000V
- Open Circuit Voltage : +20% - 0%
- Rated Current : > 1mA
- Accuracy : ± (3%rdg + 3dgt)
Loop Impedance Testing :
- Impedance Range : 20/2000©
- Rated Voltage : 230V + 10% - 15%(50Hz)
- Normal Test Current : 20©:25A/10ms
2000©:15mA/350ms max.
- Accuracy : ±(3%rdg + 8dgt)
RCD Testing :
- Test Current
(Test Current Duration) : x1/2, x1 10, 30, 100, 300, 500mA (2000ms)
Fast 150mA (50ms)
DC 10, 30, 100, 300mA (2000ms), 500mA (200ms)
Auto Ramp Goes up by 10% from 20% to 110% of Iân. 300msÃ10
- Rated Voltage : 230V + 10% - 15% 50Hz
- Accuracy : Test Current x1/2: -8%-2%
x1, FAST: +2%+8%
DC: ±10%
Auto Ramp: ±4%
Trip Time ±(1%rdg + 3dgt)
Uc Testing :
- Measuring Range : 100V
- Rated Voltage : 230V + 10% - 15% (50Hz)
- Test Current : 5mA at Iân = 10mA
15mA at Iân = 30/100mA
150mA at Iân = 300/500mA
- Accuracy : +5%+15%rdg, ±8dgt
General
- Safety Standard : IEC 61010-1 CAT.III 300V Pollution Degree 2
IEC 61557-1, 2, 3, 4, 6, 10, IEC 60529 (IP40)
- Power Source : R6 or LR6 Ã 8
- Dimensions : 175(L) Ã 115(W) Ã 86(D)mm
- Weight : 840g approx.
- Accessories : 7025 (Test Lead)
KAMP10* (Test Lead with IEC Connector)
Pouch for Test leads
Shoulder Strap
Shoulder Pad
Instruction Manual
- Optionals : 7133 (Distribution board test leads)
8212-RS232C (RS232C adaptor with "KEW Report (Software)")
8212-USB (USB adaptor with "KEW Report (Software)")

* KAMP10 (AU): Australian plug
KAMP10 (UK): British plug (13A)
KAMP10 (EU): European SHUKO plug
KAMP10 (SA): South African plug