KYORITSU 2471[Mar. 16, 2009 2:24:29]
Specification
• Water and dust proof construction. The instrument is protected against water and dust.
• True RMS for accurate measurement of non-sinusoidal waveform current.
• Selectable frequency response of 50/60Hz only or up to 1kHz.
• Automatically turns power off in about 30 minutes to conserve battery life.
AC A
(50/60Hz) : 200/2000mA/20/200/500A (True RMS)
|±1.5%rdg±6dgt (200/2000mA)
|±2%rdg±6dgt (20/200A)
|±2.5%rdg±6dgt (500A)
AC A
(WIDE) : 200/2000mA/20/200/500A (True RMS)
|±1%rdg±4dgt [50/60Hz],
|±3%rdg±4dgt [40Hz~1kHz] (200/2000mA)
|±1.5%rdg±4dgt [50/60Hz],
|±3.5%rdg±4dgt [40Hz~1kHz] (20/200A)
|±2%rdg±4dgt [50/60Hz],
|±4%rdg±4dgt [40Hz~1kHz] (500A)
Conductor Size : Ø40mm max.
Safety Standard : IEC 61010-1 CAT.III 300V IEC 61010-2-032
Effect of External
Stray Magnetic Field
Ø15mm 100A : 10mA AC max.
Frequency Response : 40~400Hz
Withstand Voltage : 3700V AC for 1 minute
Power Source : 6F22 (9V) × 1
Dimensions : 209(L) × 96(W) × 45(D)mm
Weight : 450g approx.
Accessories : 9079 (Carrying Case)
6F22 × 1
Instruction Manual
Optional : 8004/8008 (Multi-Tran)*
* These Multi-Trans can not be used for leakage current measurement.