    Solid PE Insulated & AP Sheathed ( ALPETH) Air Core Cables to ICEA S-85-625

    Solid PE Insulated & AP Sheathed ( ALPETH) Air Core Cables to ICEA S-85-625

    Quantity Order:
    Origin:
    Hong Kong SAR

    Specification :

    Application

    The cables are designed for use as subscriber distribution cables and as connection between central offices. The cables are suitable for installation in ducts, direct burial in the ground and also for aerial installation with integral suspension strand. An armoured option is offered for direct burial installations. A figure-8 self support option is offered for aerial installation.

    Standards

    • ANSI/ ICEA S-85-625

    Construction

    Conductors
    Solid annealed bare copper, 0.4/ 0.5/ 0.63/ 0.9mm, as per ASTM B-3/ class 1 of IEC 60228

    Insulation
    Solid medium or high density polyethylene as per ASTM D 1248/ IEC 60708

    Twisted Pairs
    Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk

    Cabling Element
    Twisted Pairs

    Cable Core Assembly
    Cables of 25 pairs or less are assembled into cylindrical core. Cables larger than 25 pairs are assembled into units, which are then used to form the core. Units are identified by colour coded binders

    Core Wrapping
    One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap. These tapes furnish thermal, mechanical as well as high dielectric protection between shielding and individual conductors

    Moisture Barrier
    A layer of corrugated bare aluminium tape ( 0.2mm/ 8mil) is applied longitudinally with overlap over the cable core to provide 100% electrical shielding coverage and ensure a barrier against water vapor

    Sheath
    Black low or medium density polyethylene as per ASTM D 1248/ IEC 60708, being able to withstand exposure to
    sunlight, temperature variations, ground chemicals and other environmental contaminants

    Ripcord
    Ripcord may be provided for slitting the sheath longitudinally to facilitate its removal

    Spare Pairs ( optional)
    Spare pairs may be provided for large pair cables

    Continuity Wire ( optional)
    One tinned copper drain wire may be longitudinally laid to ensure electrical continuity of the screen

    Optional Construction

    Armoured Cable
    0.15mm thick corrugated steel tape armour is applied with an overlap over an optional inner polyethylene sheath. An outer polyethylene sheath is applied over the armour

    Self-Support Cables
    A 7-strand galvanized steel strand is used as support wire. Black polyethylene sheath covers both
    core and support wire in a figure-8 construction

    Shield Options
    There are 8 different shield options which can be offered in this standard: 1) 8 mil bare aluminium tape
    2) 8 mil coated aluminium tape
    3) 5 mil copper tape
    4) 5 mil copper clad alloy steel tape
    5) 5 mil copper clad stainless steel tape
    6) 6 mil & 7 mil 194 copper alloy tape
    7) 6 mil bare steel tape
    8) 6 mil coated steel tape