Model 905V Pharmaceutical[Sep. 14, 2011 3:58:05]
Pricenego
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
Quantity24
Pack. & Deliveryunit
OriginUnited States
Model 905V Pharmaceutical
Vial O2 Analyzer

PHARMACEUTICAL APPLICATIONS

Pharmaceutical preparations packaged in vials are often gas-flushed to provide a specific atmosphere in the vial, with defined levels of oxygen, nitrogen or other gases. Depending on the product, these vials can range in size from 1 ml to 250 ml or larger. Small vials present some difficulty for oxygen analysis because the sample volume available is often quite small. A one ml vial, for example, may have only 0.5 ml of headspace gas. For direct analysis with an oxygen analyzer, the instrument must be capable of analyzing very small volumes.

FEATURES
Analyzes oxygen in all types of packages
Battery operated ( optional)
Range: 0.1 to 100% oxygen
Built-in sample pump, probe
Economically priced
0-5 Vdc analog outputs and data logging available

APPLICATIONS
-Pharmaceutical

LOW-VOLUME SENSOR DESIGN

The Model 905V sensor is designed specifically for this purpose. The oxygen sensor internal chamber has a very small volume of about 0.1 cc. The sensor is located directly behind the front panel to eliminate excessive volume. The sensor has in / out ports with a 0.03 in. ID. The vent port of the sensor connects to a short piece of narrow-bore tubing for sample exhaust and introduction of zero or calibration gases.

CALIBRATION SIMPLICITY

The oxygen sensor output is very linear through the entire range of measurement. This allows for a single point calibration to be performed anywhere in the measurement range. Span calibration is accurately done by testing room air, which should give a reading of 20.9% oxygen. Calibration standards can also be used if required by in-house test procedures.

LABORATORY OR PRODUCTION LINE

The Model 905 is a rugged benchtop unit housed in a heavy-duty metal enclosure, well suited for continuous use in routine QC testing in the laboratory. With built-in battery operation ( optional) in addition to the AC mode, this unit can be easily transported and used at remote locations such as the packaging line.

DESIGN RELIABILITY

Microprocessor based electronics are used for sensor signal processing, battery charging and on/ off control to provide high accuracy and reliability. The heavy duty, proprietary oxygen sensor is designed to provide many years of service, is totally sealed and requires no maintenance. The sensor output is compensated for ambient temperature variations
Put on Product PartnerRecommend to your friends