Products Catalog (70)
Total Suspended....
High Volume Air Sampler....
High Volume Air Sampler....
SRM 3000
Narda Broadband NBM 550
ELT 400
PORTACOUNTÂ ® RESPIRATOR....
THERMOHYGROMETERS FOR....
VELOCICALCÂ ® AIR....
COMBUSTION TEST....
See all items
Contact Information
Name:
Mr. Subchan Eko [Administrative]
E-mail:
Homepage:
www.has-environmental.com
Phone Number:
Mobile Number:
Fax Number:
Address:
Ruko Mega Grosir Cempaka Mas Blok i 12
Jakarta 10640, Jakarta
Indonesia
Average User Review
There is no review for this company
Write a review
Language :
Products Catalog
See larger image
Optical Transmissometer model OT21
Quantity Order:
Recommend to your friends
Specification
The Magee Scientific SootScanâ„¢ Model OT21 Optical Transmissometer bench top analyzer has been developed as a simple and robust way of assessing Black Carbon particulate matter (PM) from a variety of sample filters. The analysis can be easily performed in the field or the laboratory, and requires less than thirty seconds to provide optical attenuation and BC mass concentration results. This non-destructive analysis method requires no support gases or consumables. A neutral density photometric standard filter kit is available for verifying instrument calibration and validating the instrument response.
SPESIFICATION :
* Sample Collection Area
Sample is collected on a defined spot on the filter fiber tape.
Options: ‘High Sensitivity’ option provides a small,
concentrating spot for optimal performance at locations
of low concentration.
‘Extended Range’ option provides a larger, dispersing spot for optimal performance in areas of high concentration.
* Data Output
Digital data is transmitted from rear COM port. Analog output connector represents BC data as 0~5 volt DC signal, scalable in software.
* Data Recording
Data are written to recording medium once every timebase period.
- Option :
Flash memory drive is standard.
Floppy disk may be substituted.
* Consumables Required
Filter tape (sample): 1 to 4 rolls per year, depending on concentrations, and cartridge fi lters (bypass fl ow; internal purge fl ow; fl ow meter protection): approximately one per
year, each.
*Periodic Maintenance
We recommend a fl ow rate verifi cation every three months,
and cleaning the inlet assembly once per year.
*Reliability
Aethalometers have been operating at hundreds of urban,
regional, rural and remote locations on all continents,
continuously since 1986.
*Size
Instrument constructed in portable cabinet with carrying
handle: 11†high, 12†deep, 8†wide.