Specification
CD 800a, Sanwa Multimeter
Digital Multimeter
Basic Features
• 3-3/ 4 digits 4000 count
• 0.7% best accuracy
• Capacitance measurement
Not suitable for measuring condensers with large leak current
• Frequency measurement ( AC sine wave only)
• Data hold / Range hold
• Relative value
• Auto power off ( 30min.) ( cancelable)
• Low power ohm ( input voltage 0.4V) at continuity range
• Solid & protective body cover that can also be used as a tilt stand
• Chip holder behind the body cover
• Display : numeral display 4000
• Sampling rate : 3 times / sec.
AC frequency bandwidth
45-500Hz ( 4V range)
45-1KHz ( 40V range and above)
Safety
IEC61010-1 ( EN61010-1) 2001-02
CAT.III 600V Max.
Optional Accessories
Clip adapter : CL-11, TL-8IC
Specifications
DCV : 400m/ 4/ 40/ 400/ 600V
ACV : 4/ 40/ 400/ 600V
DCA : 40m/ 400mA
ACA : 40m/ 400mA
Resistance : 400/ 4k/ 40k/ 400k/ 4M/ 40MOhm
Capacitance : 50n/ 500n/ 5u/ 50u/ 100uF
Frequency : 5Hz~ 100kHz
Duty Cycle : 20~ 80%
Continuity : Buzzer sounds at between 10Ohm and 120Ohm. Open voltage : approx. 0.4V
Diode Test : Open voltage : approx. 1.5V
Bandwidth : 40~ 400Hz
Fuse : 0.5A/ 250V 1.5kA dia.5.2x20 ceramic
Battery : R6P x2
Size / Weight : H176xW104xD46mm / approx. 340g
Standard accessories included : Hand Strap, Instruction manual