Language:
Free Member
Media Surveying : : : GPS Garmin - GPS Trimble - GPS Magellan - Digital Theodolite Nikon - Total Station Topcon - Auto Level - Automatic Level Sokkia - Kompas Suunto - Kompas Brunton - Distometer - Ber Test - Handy Talky Motorola
Media Surveying : : : GPS Garmin - GPS Trimble - GPS Magellan - Digital Theodolite Nikon - Total Station Topcon - Auto Level - Automatic Level Sokkia - Kompas Suunto - Kompas Brunton - Distometer - Ber Test - Handy Talky Motorola
http://indomonster.com/media-surveying/
Untuk memudahkan dalam berbelanja, anda dapat menghubungi kami melalui email / telp / chat online. Rosi Ardiansah Tlp: 021-2880 8766 Email : rosiardiansah@gmail.com

showing 107 of 234

Products Catalog

Total Station Nikon DTM-332, Total Station Nikon DTM-352, Total Station Nikon DTM-362, Total Station Nikon DTM-532, Total Station Nikon DTM-552[Dec. 13, 2009 23:45:48]
PriceNegosiasi
Quantity Order: Add to Basket
Payment MethodTelegraphic Transfer (T/T), Cashier Order
Pack. & DeliverySet
OriginJapan
Specification
Total Station Nikon DTM-332, Total Station Nikon DTM-352, Total Station Nikon DTM-362, Total Station Nikon DTM-532, Total Station Nikon DTM-552

Total Station Nikon DTM-332
* Telescope
-Tube Length: 158mm / 6: 22 in.
-Magnification: 33x ( 21x / 41x with optional eyepieces)
-Effective diameter of objective: 45mm / 1.77 in. ( EDM: 50mm / 1.97 in.)
-Field of view: 1 ° 20 '
-Resolving power: 2.5 "
-Minimum focusing distance: 1.3M / 4: 26 ft.
* Distance measurement
Range with Nikon-specified Prisms: --
-Normal conditions: ( Ordinary haze, visibility approx. 20km / 12.5 miles)
- With reflector sheet
( 5 x 5cm) : 5 to 100m ( 328 ft to 16.4.)
- With mini prism: 1, 000m / 3, 280 ft.
- With single prism: 2, 000m / 6, 560 ft
- With triple prism: 2, 600m / 8, 530 ft.
- Good conditions: ( No haze, visibility of over 40km / 25 miles)
- With reflector sheet
( 5 x 5cm) : 5 to 100m ( 328 ft to 16.4.)
- With mini prism: 1, 200m / 3, 930 ft.
- With single prism: 2, 300m / 7540 ft.
- With triple prism: 3, 000m / 9, 840 ft.
-Accuracy ( Prism / Precise mode) : ± ( 3 + 2ppm x D) mm
± ( 3 + 3ppm x D) mm ( - 20 ° C to - 10 ° C, + 40 ° C to + 50 ° C
-Measuring interval * 1: --
- Precise mode: 1.6 sec. ( Initial 1.6 sec.)
- Normal mode: 1.0 sec. ( Initial 1.4 sec.)
-Least count: --
- Precise mode: 1mm / 0002 ft.
- Normal mode: 10mm / 0: 02 ft.
-Ambient temperature: - 20 ° C to 50 ° C / - 4 ° F to + 122 ° F
range * 2
-Atmospheric correction: --
- Temperature range: - 40 ° C to 60 ° C / - 40 ° F to + 140 ° F
- Barometric pressure: - 40 ° C to 60 ° C / - 40 ° F to + 140 ° F
- Prism Offset: - 999 to 999
* Angle measurement
- Reading system: Photoelectric detection by incremental encoder
- Horizontal angle: Diametrical ( DTM-362 / 352) , Single ( DTM-332)
- Vertical angle: Single
-Minimum increment: Degree: 1 / 5 / 10 " , Gon: 0.2 / 1 / 2mgon, MIL6400: 0005 / 0: 02 / 0, 05mil
( Degree, Gon, MIL6400)
- DIN 18723 Accuracy
( Horizontal and vertical) : 5 " / 1.5mgon ( 3" / 1.0mgon: DTM-362)
* Tilt sensor
- Type: Dual-axis ( DTM-362 / 352) , Single-axis ( DTM-332)
-Method: Liquid-electric detection
- Compensation range: ± 3 '
- Setting accuracy: 1 "
* Level vial
- Plate level vial: 30 " / 2mm
- Circular level vial: 10 ' / 2mm
Optical plummet
- Magnification: 3x
- Focusing range: 0.5m / 1.6 ft. to
-Display: Graphic LCD ( 128 x 64 dot)
Both sides ( DTM-362 / 352) , Single side ( DTM-332)
-Point memory: 10, 000 records
-Dimensions ( W x D x H) : 173 x 168 x 335mm / 6.6 x 6.8 x 13.2 in.
* Weight ( approx.)
- Main unit ( with battery) : 5.3kg / 11.7 lbs. ( DTM-362 / 352) ,
5.2kg / 11.5 lbs. ( DTM-332)
- Battery: 0.4kg / 0.9 lbs
- Carrying case: 2.4kg / 5.3 lbs
-On-board Ni-MH battery BC-65: --
- Operation time: --
- Continuous distance / angle
measurement: Approx. 16 hours * 3
-Distance / angle
measurement every 30 seconds: Approx. 27 hours
- Angle measurement: Approx. 30 hours
-Battery charger for BC-80 / 65: Approx. 2.0 hours for full recharge
-Quick charger Q-70C ( 12V DC cigarette lighter charger) : Approx. 2.0 hours ( fully discharged BC-65 requires more than one charge)

Total Station Nikon DTM-352
* Telescope
-Tube Length: 158mm / 6: 22 in.
-Magnification: 33x ( 21x / 41x with optional eyepieces)
-Effective diameter of objective: 45mm / 1.77 in. ( EDM: 50mm / 1.97 in.)
-Field of view: 1 ° 20 '
-Resolving power: 2.5 "
-Minimum focusing distance: 1.3M / 4: 26 ft.
* Distance measurement
Range with Nikon-specified Prisms: --
-Normal conditions: ( Ordinary haze, visibility approx. 20km / 12.5 miles)
- With reflector sheet
( 5 x 5cm) : 5 to 100m ( 328 ft to 16.4.)
- With mini prism: 1, 000m / 3, 280 ft.
- With single prism: 2, 000m / 6, 560 ft
- With triple prism: 2, 600m / 8, 530 ft.
- Good conditions: ( No haze, visibility of over 40km / 25 miles)
- With reflector sheet
( 5 x 5cm) : 5 to 100m ( 328 ft to 16.4.)
- With mini prism: 1, 200m / 3, 930 ft.
- With single prism: 2, 300m / 7540 ft.
- With triple prism: 3, 000m / 9, 840 ft.
-Accuracy ( Prism / Precise mode) : ± ( 3 + 2ppm x D) mm
± ( 3 + 3ppm x D) mm ( - 20 ° C to - 10 ° C, + 40 ° C to + 50 ° C
-Measuring interval * 1: --
- Precise mode: 1.6 sec. ( Initial 1.6 sec.)
- Normal mode: 1.0 sec. ( Initial 1.4 sec.)
-Least count: --
- Precise mode: 1mm / 0002 ft.
- Normal mode: 10mm / 0: 02 ft.
-Ambient temperature: - 20 ° C to 50 ° C / - 4 ° F to + 122 ° F
range * 2
-Atmospheric correction: --
- Temperature range: - 40 ° C to 60 ° C / - 40 ° F to + 140 ° F
- Barometric pressure: - 40 ° C to 60 ° C / - 40 ° F to + 140 ° F
- Prism Offset: - 999 to 999
* Angle measurement
- Reading system: Photoelectric detection by incremental encoder
- Horizontal angle: Diametrical ( DTM-362 / 352) , Single ( DTM-332)
- Vertical angle: Single
-Minimum increment: Degree: 1 / 5 / 10 " , Gon: 0.2 / 1 / 2mgon, MIL6400: 0005 / 0: 02 / 0, 05mil
( Degree, Gon, MIL6400)
- DIN 18723 Accuracy
( Horizontal and vertical) : 5 " / 1.5mgon ( 3" / 1.0mgon: DTM-362)
* Tilt sensor
- Type: Dual-axis ( DTM-362 / 352) , Single-axis ( DTM-332)
-Method: Liquid-electric detection
- Compensation range: ± 3 '
- Setting accuracy: 1 "
* Level vial
- Plate level vial: 30 " / 2mm
- Circular level vial: 10 ' / 2mm
Optical plummet
- Magnification: 3x
- Focusing range: 0.5m / 1.6 ft. to
-Display: Graphic LCD ( 128 x 64 dot)
Both sides ( DTM-362 / 352) , Single side ( DTM-332)
-Point memory: 10, 000 records
-Dimensions ( W x D x H) : 173 x 168 x 335mm / 6.6 x 6.8 x 13.2 in.
* Weight ( approx.)
- Main unit ( with battery) : 5.3kg / 11.7 lbs. ( DTM-362 / 352) ,
5.2kg / 11.5 lbs. ( DTM-332)
- Battery: 0.4kg / 0.9 lbs
- Carrying case: 2.4kg / 5.3 lbs
-On-board Ni-MH battery BC-65: --
- Operation time: --
- Continuous distance / angle
measurement: Approx. 16 hours * 3
-Distance / angle
measurement every 30 seconds: Approx. 27 hours
- Angle measurement: Approx. 30 hours
-Battery charger for BC-80 / 65: Approx. 2.0 hours for full recharge
-Quick charger Q-70C ( 12V DC cigarette lighter charger) : Approx. 2.0 hours ( fully discharged BC-65 requires more than one charge)
Acuration: 5 "

Total Station Nikon DTM-362
* Telescope
-Tube Length: 158mm / 6: 22 in.
-Magnification: 33x ( 21x / 41x with optional eyepieces)
-Effective diameter of objective: 45mm / 1.77 in. ( EDM: 50mm / 1.97 in.)
-Field of view: 1 ° 20 '
-Resolving power: 2.5 "
-Minimum focusing distance: 1.3M / 4: 26 ft.
* Distance measurement
Range with Nikon-specified Prisms: --
-Normal conditions: ( Ordinary haze, visibility approx. 20km / 12.5 miles)
- With reflector sheet
( 5 x 5cm) : 5 to 100m ( 328 ft to 16.4.)
- With mini prism: 1, 000m / 3, 280 ft.
- With single prism: 2, 000m / 6, 560 ft
- With triple prism: 2, 600m / 8, 530 ft.
- Good conditions: ( No haze, visibility of over 40km / 25 miles)
- With reflector sheet
( 5 x 5cm) : 5 to 100m ( 328 ft to 16.4.)
- With mini prism: 1, 200m / 3, 930 ft.
- With single prism: 2, 300m / 7540 ft.
- With triple prism: 3, 000m / 9, 840 ft.
-Accuracy ( Prism / Precise mode) : ± ( 3 + 2ppm x D) mm
± ( 3 + 3ppm x D) mm ( - 20 ° C to - 10 ° C, + 40 ° C to + 50 ° C
-Measuring interval * 1: --
- Precise mode: 1.6 sec. ( Initial 1.6 sec.)
- Normal mode: 1.0 sec. ( Initial 1.4 sec.)
-Least count: --
- Precise mode: 1mm / 0002 ft.
- Normal mode: 10mm / 0: 02 ft.
-Ambient temperature: - 20 ° C to 50 ° C / - 4 ° F to + 122 ° F
range * 2
-Atmospheric correction: --
- Temperature range: - 40 ° C to 60 ° C / - 40 ° F to + 140 ° F
- Barometric pressure: - 40 ° C to 60 ° C / - 40 ° F to + 140 ° F
- Prism Offset: - 999 to 999
* Angle measurement
- Reading system: Photoelectric detection by incremental encoder
- Horizontal angle: Diametrical ( DTM-362 / 352) , Single ( DTM-332)
- Vertical angle: Single
-Minimum increment: Degree: 1 / 5 / 10 " , Gon: 0.2 / 1 / 2mgon, MIL6400: 0005 / 0: 02 / 0, 05mil
( Degree, Gon, MIL6400)
- DIN 18723 Accuracy
( Horizontal and vertical) : 5 " / 1.5mgon ( 3" / 1.0mgon: DTM-362)
* Tilt sensor
- Type: Dual-axis ( DTM-362 / 352) , Single-axis ( DTM-332)
-Method: Liquid-electric detection
- Compensation range: ± 3 '
- Setting accuracy: 1 "
* Level vial
- Plate level vial: 30 " / 2mm
- Circular level vial: 10 ' / 2mm
Optical plummet
- Magnification: 3x
- Focusing range: 0.5m / 1.6 ft. to
-Display: Graphic LCD ( 128 x 64 dot)
Both sides ( DTM-362 / 352) , Single side ( DTM-332)
-Point memory: 10, 000 records
-Dimensions ( W x D x H) : 173 x 168 x 335mm / 6.6 x 6.8 x 13.2 in.
* Weight ( approx.)
- Main unit ( with battery) : 5.3kg / 11.7 lbs. ( DTM-362 / 352) ,
5.2kg / 11.5 lbs. ( DTM-332)
- Battery: 0.4kg / 0.9 lbs
- Carrying case: 2.4kg / 5.3 lbs
-On-board Ni-MH battery BC-65: --
- Operation time: --
- Continuous distance / angle
measurement: Approx. 16 hours * 3
-Distance / angle
measurement every 30 seconds: Approx. 27 hours
- Angle measurement: Approx. 30 hours
-Battery charger for BC-80 / 65: Approx. 2.0 hours for full recharge
-Quick charger Q-70C ( 12V DC cigarette lighter charger) : Approx. 2.0 hours ( fully discharged BC-65 requires more than one charge)
Acuration: 3 "

Total Station Nikon DTM-532
* Telescope
-Tube length: 158 mm / 6: 22 in.
-Image: Erect
-Effective diameter of objective: 45mm / 1.77 in.
( EDM: 50 mm / 1.97 in.)
-Magnification: 33 x ( 21 x / 41 x with optional eyepieces)
-Field of view: 1 ° 20 '
( 2.3 m at 100 m / 2.3 ft. At 100 ft.)
-Resolving power: 2.5 "
-Minimum focusing distance: 1.3 m / ft 4: 26.
-Reticle illumination: Provided ( 3 steps)
* Distance measurement ( with Nikon specified prism)
-Under good conditions: ( no haze with visibility over 40 km / 25 miles)
-With reflector sheet
( 5 x 5cm) : 5 to 100 m / 16.4 ft to 328.1.
-With mini prism: 1, 100m / 3, 600 ft.
-With single prism: 2, 700 m / 8, 900 ft.
-With triple prism: 3, 600 m / 11, 800 ft.
With nine-Prisms: 4, 400 m / 14, 400 ft.
-Under normal conditions: ( ordinary haze with visibility about 20 km / 12.5 miles)
-With reflector sheet
( 5 x 5cm) : 5 to 100 m / 16.4 ft to 328.1.
-With mini prism: 950 m / 3, 100 ft.
-With single prism: 2, 400 m / 7, 900 ft.
-With triple prism: 3, 100 m / 10, 200 ft.
With nine-Prisms: 3, 700 m / 12, 100 ft.
-Reflectorless mode ( white target * ) : --
-Readout display: 9999.9999 m / 29999.999 ft.
* Accuracy
-Precise mode: ± ( 2 + 2ppm x D) mm
-Normal mode: ± ( 4 + 2ppm x D) mm
* Least count
-Precise mode: 0.1 mm / 1 mm, 0.0005 ft. / 0002 ft. selectable
-Normal mode: 1 mm / 10 mm, 0002 ft. / 0: 02 ft. selectable
* Measuring intervals ( DTM-502 series) * 2
Precise mode-mode: 1.0 sec. ( Initial 1.0 sec.)
Normal mode-mode: 0.5 sec. ( Initial 1.0 sec.)
* Atmospheric correction
-Temperature range: -40 ° C to 60 ° C / -40 ° F to 140 ° F
-Barometric pressure: 400 to 999 mhg / 533 to 1332 hpa / 15.8 to 39.3 in.hg
-Prism offset correction: -999 to 999
-Reading system: Photoelectric detection by incremental encoder
( Diametrical detection for H / V circles)
-Circular diameter: 79 mm
-Acuration: 2 "

Total Station Nikon DTM-552
* Telescope
-Tube length: 158 mm / 6: 22 in.
-Image: Erect
-Effective diameter of objective: 45mm / 1.77 in.
( EDM: 50 mm / 1.97 in.)
-Magnification: 33 x ( 21 x / 41 x with optional eyepieces)
-Field of view: 1 ° 20 '
( 2.3 m at 100 m / 2.3 ft. At 100 ft.)
-Resolving power: 2.5 "
-Minimum focusing distance: 1.3 m / ft 4: 26.
-Reticle illumination: Provided ( 3 steps)
* Distance measurement ( with Nikon specified prism)
-Under good conditions: ( no haze with visibility over 40 km / 25 miles)
-With reflector sheet
( 5 x 5cm) : 5 to 100 m / 16.4 ft to 328.1.
-With mini prism: 1, 100m / 3, 600 ft.
-With single prism: 2, 700 m / 8, 900 ft.
-With triple prism: 3, 600 m / 11, 800 ft.
With nine-Prisms: 4, 400 m / 14, 400 ft.
-Under normal conditions: ( ordinary haze with visibility about 20 km / 12.5 miles)
-With reflector sheet
( 5 x 5cm) : 5 to 100 m / 16.4 ft to 328.1.
-With mini prism: 950 m / 3, 100 ft.
-With single prism: 2, 400 m / 7, 900 ft.
-With triple prism: 3, 100 m / 10, 200 ft.
With nine-Prisms: 3, 700 m / 12, 100 ft.
-Reflectorless mode ( white target * ) : --
-Readout display: 9999.9999 m / 29999.999 ft.
* Accuracy
-Precise mode: ± ( 2 + 2ppm x D) mm
-Normal mode: ± ( 4 + 2ppm x D) mm
* Least count
-Precise mode: 0.1 mm / 1 mm, 0.0005 ft. / 0002 ft. selectable
-Normal mode: 1 mm / 10 mm, 0002 ft. / 0: 02 ft. selectable
* Measuring intervals ( DTM-502 series) * 2
Precise mode-mode: 1.0 sec. ( Initial 1.0 sec.)
Normal mode-mode: 0.5 sec. ( Initial 1.0 sec.)
* Atmospheric correction
-Temperature range: -40 ° C to 60 ° C / -40 ° F to 140 ° F
-Barometric pressure: 400 to 999 mhg / 533 to 1332 hpa / 15.8 to 39.3 in.hg
-Prism offset correction: -999 to 999
-Reading system: Photoelectric detection by incremental encoder
( Diametrical detection for H / V circles)
-Circular diameter: 79 mm
-Acuration: 2 "

We also provide service, calibration, replacement sperpart, software updates for all type and brand of total station with experts to the field.

We serve orders from all over Indonesia. Shipping cost vary depending on destination. Please message the product and then do a confirmation via email / tel / chat online. ( For the Jakarta area free postage! )
Rosi Ardiansah
Hp: 085710474131
Phone: 021-28808766
Email: rosiardiansah@ gmail.com
Chat Online: rosiardiansah