MagneW Two-wire PLUS Loop Powered Electromagnetic Flow Meter - Azbil Yamatake[Feb. 13, 2012 2:25:01]
Specification
MagneW Two-wire PLUS Loop Powered Electromagnetic Flow Meter
Brand : Azbil Yamatake
Overview :
The MagneW Two-wire PLUS dramatically reduces wiring costs without scarificing performance or aaccuracy through loop-powered technology. Installation and maintanence costs are lowered when compared to devices requiring four-wire cable runs. The MagneW Two-wire PLUS also can be used as an upgrade to existing two-wire flow meters with no added wiring costs.
Converter
+ Model No.Integral : MTG18A-; Remote: MTG14C-
+ Type : Integral Style or Remote Style
+ Power Supply : Loop Power, 15.6 to 42Vdc
+ Output : 4-20mA, Open Collector Pulse, Contact
+ Power Consumption : 0.1 to 0.5W ( depending on output current value)
+ Min. Fluid Conductivity : 10µ S/ cm
+ Functions : Damping, Dropout setting, Empty pipe detection, Low flow cutoff, Electrode Scale, etc.
+ Communications : HART, DE Protocol
+ Display : LCD main display, 8-digits, 7-segments; sub-display 2 lines 16 digits
+ Data Setting Interface : 4 key switches on LOI, remote communications
+ Accuracy : + / -0.5% of rate
+ Electronics Housing : Aluminum alloy with baked acrylic or epoxy coating
+ Ambient Temperature : -4 to 140 ¢ ª F ( -20 to 60 ¢ ª C)
+ Ambient Humidity : 5 to 100% RH ( non-condensing)
+ Enclosure Rating : IEC IP67, NEMA 4X
+ Mounting : Wall or 2 in. ( 50mm) pipe options
Detector
+ Model No. Integral : MTG18A-; Remote: MTG18B-
+ Type : Integral Style or Remote Style
+ Approvals : FM/ CSA, Class I Div. 1, Groups B, C and D ( Integral Only)
+ Liner Materials : PFA
+ Electrode Material : 316L SS, Hastelloy C276, Titanium, Zirconium, Tantalum, Tungsten Carbide, Platinum-Iridium, others
+ Grounding Rings : 316 SS, Hastelloy C276, Titanium, Zirconium, Tantalum, Platinum, others
+ Housing : 304 SS
+ Flow Tube : 304 SS
+ Piping Connection : Wafer: ANSI Class 150 & 300; Flange: ANSI Class 150 & 300
+ Min. Fluid Conductivity : 10 µ S/ cm
+ Fluid Temperature : -4 to + 266 ¢ ª F ( -20 to + 130 ¢ ª C)
+ Ambient Temperature : -14 to + 140 ¢ ª F ( -20 to + 60 ¢ ª C)
+ Ambient Humidity : 5 to 100% RH ( non-condensing)
+ Enclosure Rating : IEC IP67, NEMA 4X
Benefits :
+ Enhanced signal conditioning circuitry provides excellent noise and spike immunity
+ High stable and repeatable output with ± 0.5% of rate accuracy
+ Minimum process fluid conductivity requirement of 10¼ S/ cm provides maximum applicability
+ Electrode Status Diagnostic function diagnoses empty pipe condition or electrode scaling
+ Available in wafer of flanged designs
+ Both Integral and Remote configurations are available for maximum flexibility
+ Detector sizes from 0.1" to 8" ( 2.5 to 200mm) are available
Put on Product PartnerRecommend to your friends