Specification :
1. Brief Introduction
Electromagnetic Flowmeter is of perfect performance and reliability. Based on the successfully proved flow technology on aboard, the flow meter is widely used in industries of petroleum, chemical engineering, metallurgy, food, electric power, papermaking, water treatment, etc.
2. Diameter and flow of electromagnetic flow meter selection
DN mm Measurable Flow
Range ( m3/ h) Effective Flow
Range ( m3/ h) DN mm Measurable Flow
Range ( m3/ h) Effective Flow
Range ( m3/ h)
10 0.0142^ 3.3912 0.0848^ 2.826 300 12.717^ 3052 76.302^ 2543
15 0.0318^ 7 .6302 0.1908^ 6.3585 350 17.31^ 4154 103.86^ 3461
20 0.0566^ 13.5648 0.3392^ 11.3 04 400 22.61^ 5425 135.65^ 4521
25 0.0883^ 21.195 0.5298^ 17.6625 450 28.62^ 6867 171.68^ 5722
32 0.1447^ 34.7258 0.8682^ 29.9382 500 35.33^ 8478 211.95^ 7065
40 0.2261^ 54.2592 1.3565^ 45.216 600 50.87^ 12208 305.2^ 10173
50 0.3533^ 84.78 2.1 195^ 70.65 700 69.24^ 16616 415.4^ 13847
65 0.5970^ 143.28 3.5819^ 119.39 800 90. 44^ 21703 542.6^ 18086
80 0.9044^ 217.03 5.4259^ 180.86 900 114.46^ 27468 686.7^ 2 2890
100 1.413 ^ 339.12 8.478^ 282.6 1000 141.3^ 33912 847.8^ 28260
125 2.2079^ 529.87 13.2468^ 4 41.56 1200 203.5^ 48833 1221^ 40694
150 3.1793^ 763 19.0755^ 635.85 1400 277^ 664 67 1662^ 55389
200 5.652^ 1356 33.912^ 1130.4 1600 361.8^ 86814 2171^ 72345
250 8 .8313^ 2119 52.9875^ 1766 1800 457.9^ 109874 2747^ 91562
3. Characteristics
Measurement is independent of fluid density, viscosity, humidity, temperature, pressure and conductivity.
There are no obstacle parts in the measuring tube, no pressure loss to the tube of which the straight part is of low requirement.
The sensor with grounded electrode guarantees the grounding well.
The sensor with advanced processing technology is of nice resistance to the negative pressure.
The converter makes the reading easily under the sun or in the dark room.
Installed on the tube forming with the standard type on angle equal to or small than 90° , the revolving display screen improves the visibility of the integrated flow meter.
In bad environment parameter can be without uncovering the cover of the converter set up through the infra-red ray touch nub.
The converter has alarm output function of self-diagnosis, empty load test, high and low limit of the flow, two-stage flow value, etc.
It is used not only in general process test, but also in the test of mine pulp, paper pulp and pastry liquid.
The sensor of high-pressure electromagnetic flowmeter is made with patent technology and specially applied in industries of petroleum, chemical engineering, etc.