Welcome to
CV. GALUNG PRIMA

Free Member
CV. GALUNG PRIMA
Indonesia

FLAMEPROOF MOTOR CEMP

CEMP FLAMEPROOF - EXPLOSIONPROOF MOTORS

INDUSTRIAL MOTOR :

- PUMP MOTORS

- 3 PHASAMOTORS

- AC MOTORS

- DC MOTORS

- ELECTRIC MOTORS

- EXPLOSION PROOF MOTORS

- GEAR MOTORS

- HIGH SPEED MOTORS

- HIGH TORQUE MOTORS

- HYDRAULIC MOTORS

- INDUCTION MOTORS

- LOW SPEED HIGH TORQUE MOTORS

- LOW VOLTAGE MOTORS

- LINEAR MOTORS

- MEDIUM VOLTAGE MOTORS

- METRIC (IEC) MOTORS

- OEM MOTORS

- PANCAKE MOTORS

- PERMANENT MAGNETIC MOTORS

- PERMANENT SPILIT CAPACITOR (PSC) MOTORS

- PIEZOELECTIC MOTORS

- PNEUMETIC (AIR) MOTORS

- REVERSIBLE MOTORS

- SERVO MOTORS

- STEPPER MOTORS

- SUBMERSIBLE MOTORS

- SYNCHRONOUS MOTORS

- UNIVERSAL MOTORS

- VARIABLE SPEED MOTORS

- WATERPROOF MOTORS

- MOTOR CONTROLLER

- MOTOR STARTER


The Products :

1. Flameproof - Explosion Proof Motors :
- Series A cast-iron :
* To Norms IEC 60079-0, IEC 60079-1, IEC 60079-7
* Ex-d, Ex-de
* Frame size 63 ÷ 315
* ATEX category 1M2, 2G, 2GD
* Group I (mine), IIB, IIC
* Temperature class T3, T4, T5, T6
* To Norms IEC 61241-0, IEC 61241-1
* A21 - tD
* Protection IP55, IP65
* Maximum surface temperature [°C] T150, T135, T100, T85
* To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
* Power 0.12 ÷ 200 kW
* Three-phase 1 or 2 speed
* Single-phase (frame size 63-100)

- Series F Aluminium :
* IEC 60079-0, IEC 60079-1, IEC 60079-7
* Ex-d, Ex-de
* Frame size 56 ÷ 80
* ATEX category 2D, 2G, 2GD
* Group IIB, IIC
* Temperature class T4, T5, T6
* To Norms IEC 61241-0, IEC 61241-1
* A21 - tD
* Protection IP55, IP65
* Maximum surface temperature [°C] T125, T85, T70
* To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
* Power 0.06 ÷ 1.5 kW
* Three-phase 1 or 2 speed
* Single-phase
* Ventilated, unventilated
* PAD mounting

2. Flameproof - Explosion Proof Brake Motors :
- Series D, H, cast-iron :
* To Norms IEC 60079-0, IEC 60079-1, IEC 60079-7
* Ex-d, Ex-de
* Frame size 63 ÷ 250
* ATEX category 2G, 2GD
* Group IIB, IIC
* Temperature class T3, T4, T5
* To Norms IEC 61241-0, IEC 61241-1
* A21 - tD
* Protection IP55, IP65
* Maximum surface temperature [°C] T150, T135, T100, T85
* To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
* Power 0.18 ÷ 55 kW
* Three-phase 1 or 2 speed, inverter
* A.C. or D.C. disk brake

- Series F-F Aluminium :
* To Norms IEC 60079-0, IEC 60079-1, IEC 60079-7
* Ex-d, Ex-de
* Frame size 63 ÷ 80
* ATEX category 2D, 2G, 2GD
* Group IIB, IIC
* Temperature class T4, T5
* To Norms IEC 61241-0, IEC 61241-1
* A21 - tD
* Protection IP55, IP65
* Maximum surface temperature [°C] T125, T85, T70
* To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
* Power 0.12 ÷ 1.5 kW
* Three-phase 1 or 2 speed, inverter
* A.C. or D.C. disk brake

3. Inverter Flameproof - Explosion Proof Motors :
- Series A cast-iron :
* To Norms IEC 60079-0, IEC 60079-1, IEC 60079-7
* Ex-d, Ex-de
* Frame size 63 ÷ 315
* ATEX category 2G, 2GD
* Group IIB, IIC
* Temperature class T3, T4, T5
* To Norms IEC 61241-0, IEC 61241-1
* A21 - tD
* Protection IP55, IP65
* Maximum surface temperature [°C] T150, T135
* To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
* Power 0.12 ÷ 200 kW
* Three-phase
* Self cooled (IC411); forced cooling (IC416)

- Series F Aluminium :
* IEC 60079-0, IEC 60079-1, IEC 60079-7
* Ex-d, Ex-de
* Frame size 56 ÷ 80
* ATEX category 2D, 2G, 2GD
* Group IIB, IIC
* Temperature class T4, T5, T6
* To Norms IEC 61241-0, IEC 61241-1
* A21 - tD
* Protection IP55, IP65
* Maximum surface temperature [°C] T125, T85, T70
* To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
* Power 0.06 ÷ 1.5 kW
* Three-phase 1 or 2 speed
* Single-phase
* Self cooled (IC411); forced cooling (IC416); unventilated (IC418)
* PAD mounting

4. Flameproof - Explosion Proof Motors for Special Applications :
- Mechanical Variants :
* Protection IP56, IP65, IP66
* Special flanges and shafts
* Without terminal box (loose leads)
* Terminal box on side
* Uni-directional bearings, locked bearings or special bearings
* SPM probe (vibrations measurement)
* Heaters

- Electrical Variants :
* Special voltage and frequency
* Bimetallic thermal protection (NC, NO), thermistor (PTC), platinum resistor (PT100)
* Single-phase with permanent capacitor
* Single-phase with centrifugal switch

5. Non Sparking Motors :
- Series N, AN :
* Norms IEC 60079-0, IEC 60079-15
* Ex-nA
* Frame size (aluminium) 63 ÷ 200
certificated by manufacturer
* Frame size (cast-iron) 63 ÷ 315
certificated by Notified Body
* ATEX category 3G
* Group II
* Temperature class T3
* Protection IP55
* Power 0.12 ÷ 200 kW
* Three-phase 1 speed

6. Motor For Dust :
- Series ND, AP :
* To Norms IEC 61241-0, IEC 61241-1
* A22 - tD
* Frame size (aluminium) 63 ÷ 200
* Frame size (cast-iron) 63 ÷ 315
* ATEX category 3D
* Group II
* Protection IP55
* Maximum surface temperature [°C] T150, T125
* Power 0.12 ÷ 200 kW
* Three-phase 1 speed

7. Totally Enclosed Fan Cooled Motors :
- Series C :
* To norm IEC
* Frame size (aluminium) 63 ÷ 200
* Frame size (cast-iron) 225 ÷ 315
* Protection IP55
* Power 0.12 ÷ 132 kW
* Three-phase 1 or 2 speed

8. Flame Proof Electric Pumps for Printing Machines :
- Series AT :
* Submersible centrifugal electric pumps
* To Norms IEC 60079-0, IEC 60079-1,IEC 60079-7, EN 1127-1, EN 13463-1, prEN 13463-5
* Ex-d, Ex-de
* Group IIB, IIC
* Output over 300 l/min
* Head up to 8 m
* Stem length from 170 to 550 mm
* Special applications

- Series XT - Detachable motor from the pump unit :
* Submersible centrifugal electric pumps
* To Norms IEC 60079-0, IEC 60079-1, IEC 60079-7, EN 1127-1, EN 13463-1, prEN 13463-5
* Ex-d, Ex-de
* Group IIB, IIC
* Output over 200 l/min
* Head up to 4 m
* Stem length from 170 to 350 mm
* Special applications

9. Electric Pumps for Machine Tools :
- Series T :
* Submersible centrifugal electric pumps
* To norm IEC
* Output over 300 l/min
* Head up to 8 m
* Stem length from 90 to 550 mm
* Special applications
SelectThe Check Box and clickoror
showing 1-2 of 2
Show items per page
  • FLAMEPROOF - EXPLOSIONPROOF MOTOR CEMP

    FLAMEPROOF -....

    NEGOTIABLE

    DESCRIPTION

    Flameproof - Explosionproof Motors

    1. Series A cast-iron

    - To Norms IEC 60079-0, IEC 60079-1, IEC 60079-7

    - Ex-d, Ex-de

    - Frame size 63 Ã · 315

    - ATEX....

  • INVERTER FLAMEPROOF - EXPLOSIONPROOF MOTOR CEMP

    INVERTER FLAMEPROOF ....

    NEGOTIABLE

    DESCRIPTION

    Inverter Flameproof - Explosionproof Motors

    1. Series A cast-iron

    - To Norms IEC 60079-0, IEC 60079-1, IEC 60079-7

    - Ex-d, Ex-de

    - Frame size 63 Ã · 315
    ....

SelectThe Check Box and clickoror
showing 1-2 of 2