KOEHLER K47000 Autoignition Apparatus[Jun. 4, 2011 2:20:14]
PriceInquiry
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
Pack. & Delivery1 unit
OriginUnited States
Test Method
Determines the lowest temperature at which the vapors of a liquid or solid chemical sample will self-ignite under prescribed laboratory conditions. The temperatures at which ‘ cool flame’ and ‘ hot flame’ ignitions occur, as evidenced by sudden temperature increases in the sample flask, are measured and recorded, and the delay time between introduction of the sample and ignition is timed.

Features and Benefits
• Conforms to ASTM E659 specifications

• Digital furnace temperature control

• Digital flask temperature display

K47000 Autoignition Apparatus
Modified crucible furnace with digital thermocouple readout of flask temperature at prescribed points per ASTM specifications. Linearized analog output permits connection to a strip chart recorder or datalogging instrument. Furnace provides rapid response and ± 1° C stability throughout the operating range of 200 to 1200° C. Cylindrical heating chamber provides excellent radial temperature uniformity. Furnace cover has ports for flask exterior thermocouples, and a borosilicate glass thermocouple tube is provided to assure correct positioning of the gas temperature thermocouple inside the test flask. Thermocouples plug directly into the furnace control unit for quick disconnection when removing the flask. A hinged holder in the cover facilitates handling of the test flask. Adjustable mirror permits safe viewing of the flask interior during testing. Control panel has temperature controls and digital thermocouple readout with four-position selector switch.

Specifications
Conforms to: ASTM E659

Temperature Range: 200 to 1200° C

Temperature Control: digital setpoint solid state controller accurate to within ± 1° C

Flask Temperature Display: 0-1200° C, with four position selector switch

Electrical Requirements
220-240V 50/ 60Hz, Single Phase, 7.7A

Included Accessories
Test Flask, 500mL
Thermocouples ( 4)

Dimensions lxwxh, in.( cm)
Furnace: 15x15x22 ( 38x38x56)
Control Cabinet: 22x10x14 ( 56x25x36)
Net Weight: 72 lbs ( 32.8kg)

Shipping Information
Shipping Weight: 98 lbs ( 44.5kg)
Dimensions: 16.3 Cu. ft.

Ordering Information
Catalog
Number Product Description Electrical Requirements
K47000 Autoignition Apparatus 220-240V, 50/ 60Hz

Accessories
Catalog
Number Product Description Electrical Requirements
362-001-000 Syringe, 1mL
K470-0-1-14 Needle, 6" , stainless steel
308-115-001 Recorder
Records signal from the internal gas thermocouple in strip chart form. 115V 50/ 60Hz
308-230-006 Recorder 220-240V 50/ 60Hz
374-115-001 Hot Air Gun
For purging product gases between tests 115V 50/ 60Hz
374-230-001 Hot Air Gun 220-240V 50/ 60Hz
332-003-007 Test Flask, 500mL