Free Member 
Language :
CV. ANDALAN PRIMA SEJAHTERA
CV. ANDALAN PRIMA SEJAHTERA
http://indomonster.com/cv_aps/
CV. ANDALAN PRIMA SEJAHTERA
Contact Information
Name:
Mrs. REGINA / VANNY / VITHA [Director/CEO/General Manager]
E-mail:
Homepage:
Instant Messaging:
Y!: andalan1974@yahoo.com 
Phone Number:
Phone number of Mrs. REGINA / VANNY / VITHA at JAKARTA
Mobile Number:
Mobile number of Mrs. REGINA / VANNY / VITHA at JAKARTA
Fax Number:
Fax number of Mrs. REGINA / VANNY / VITHA at JAKARTA
Address:
Jl. muchtar tabrani, Perum Bintang Metropol Blok A7/16 Bekasi
JAKARTA, Jakarta
Indonesia
Average User Review

There is no review for this company

Write a review

Products Catalog

COPPER STRIP CORROSION BY LIQUEFIED PETROLEUM[Mar. 24, 2009 2:17:44]
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
Pack. & Delivery1 unit
OriginUnited States

Specification

Test Method :

Tests the corrosiveness of LPG to copper by immersion of a polished test strip in the sample inside a test cylinder at elevated temperature. After one hour the test strip is removed and compared against the ASTM Copper Strip Corrosion Standards. Complete test consists of LPG Corrosion Test Cylinders, Water Bath, Copper Strips, Polishing Materials and the ASTM Copper Strip Corrosion Test Standards.

Features and Benefits :

• Conforms to ASTM D1838 and related specifications

• Four-sample testing capability

K39900 LPG Copper Strip Corrosion Test Water Bath
Thermostatically controlled water bath submerges four LPG Corrosion Test Cylinders in an upright position. Controls temperature at 100±1°F (37.8±0.5°C) per ASTM specifications. Soxhlet reflux condenser and constant water level device maintain proper working depth. Polished stainless steel double-wall construction. Fully insulated.

Specifications
Conforms to the specifications of:
ASTM D1838; GPA 2140; ISO 6251

Capacity: four (4) LPG Corrosion Test Cylinders

Maximum Temperature: 221°F (105°C)

Temperature Control Stability: ±1°F (±0.5°C)

Heater Range: 0-750W

Bath Medium: 3.8 gal (14.4L) Water

Electrical Requirements :
115V 50/60Hz, Single Phase, 6.5A
220-240V 50/60Hz, Single Phase, 3.4A

Dimensions : lxwxh,in.(cm)
12x10x24 (30x25x61)
Net Weight: 19 lbs (8.6kg)

Shipping Information :
Shipping Weight: 27 lbs (12.2kg)
Dimensions: 5.3 Cu. ft.
Ordering Information

Catalog
Number
Product Description
Electrical Requirements
K39900
LPG Corrosion Test Water Bath 115V 50/60Hz
K39990 LPG Corrosion Test Water Bath 220-240V 50/60Hz
Accessories

Catalog
Number Product Description
K40200 Copper Strip for LPG
12.5x1.5-3.0x75mm with 3.2mm hole per ASTM specifications
K40100 Connecting Tubing
Sulfur-free plastic-lined tubing for connection of test cylinder valve to sample source. With 1/4" stainless steel and aluminum connectors. 24" long
K25100 ASTM Copper Strip Corrosion Test Standards
Colored reproductions of tarnished strips encased in a plastic plaque.
380-240-001 Silicone Carbide Paper, 240-grit
For polishing copper strips prior to testing. Pack of 50 sheets.
380-150-000 Silicone Carbide Grain, 150-grit
For final polishing of copper strips prior totesting. 1 lb package.
K25000 Polishing Vise
Holds copper strip firmly in place without marring the edges. Stainless steel, mounted on a composition base.
K25090 Multi-Strip Polishing Vise
Similar to K25000 but capable of holding four strips at a time.
250-000-12F ASTM 12F Thermometer
Range: –5 to +215°F
250-000-12C ASTM 12C Thermometer
Range: –20 to +102°C
380-150-001 Silicone Carbide Paper, 150-grit
For polishing copper strips prior to testing.
Pack of 50 sheets
When inquiring about NIST traceable certified thermometers, please refer to the catalog number for the corresponding thermometer and replace the middle three zeros in the catalog number with 004. Example: 251-000-01C ASTM 1C Thermometer would be 251-004-01C ASTM 1C Certified Thermometer.