Specification
Applicable model 5010/5020 (*),
6300, 6310
* When you use the sensors with KEW5010/5020, please check the "Applicable model list" to check if your KEW5010/5020 can be used with the sensors.
Conductor size : ¦40
Rated current : AC 500A
Output voltage : AC 500mV/500A (AC 1mV/A)
Accuracy : ±0.5%rdg±0.1mV (50/60Hz)
±1.0%rdg±0.2mV (40Hz~1kHz)
Phase Shift : within ±1.0º (45~65Hz)
Withstand voltage : AC 5350V for 5 seconds
Cable length : Approx. 3m
Output connector : MINI DIN 6pin
Operating temperature ranges : 0~50ºC, less than 85% RH (without condensation)
Output impedance : Approx. 2©
Applicable standards : IEC 61010-1:2001,
IEC 61010-2-032:2002,
CAT.III 600V pollution degree 2
Dimensions : 128(L) x 81(W) x 36(D) mm
Weight : Approx.260g
Accessories : 9095 (Portable case), Instruction manual, Cable marker
Option : 7146 (Banana ¦4 adjuster plug)
7185 (Extension Cable)