HIOKI 2300 Series REMOTE MEASUREMENT SYSTEM[Mar. 6, 2009 3:28:23]
Specification
Easily Construct a Centralized Data Management System for Monitoring Multiple Locations
LAN Module that paves the way for a low cost remote measuring system by utilizing existing data network :
- Various measurement modules for temperature and humidity, instrumentation, and pulse
- Power measurement module for multiple circuits
- Large internal memory to avoid data loss due to communication problems
- Communication module with built-in real-time clock tracks the data of each measurement module to the second
- SS Air Module for constructing wireless systems
Basic specifications :
HUMIDITY MODULE
2301-20 : Temperature 1ch and humidity 1ch.
Use with optional sensor 9764-50
Temperature: -40.0 to 85.0°C
Humidity: 0.0 to 100%RH
Pt MODULE
2302-20 : Temperature 2ch (Pt100)
2 types of platinum resistance thermo sensors available
TC MODULE
2303-20 : 2ch temperature measurement using thermocouples (K, E, J, T). 4 TC types available
PULSE MODULE
2304-21 : For 2ch pulse input (voltage,contact), maximum 16M pulses/interval
Input pulse: 4kHz max. (voltage/electroniccontact signal)
25Hz max. (mechanical contact signal)
INSTRUMENTATION MODULE
2305-20 : Voltage / current 2ch measurement, for 4-20mA, 1-5V instrumentation signals
MULTI-FUNCTION MODULE
2306 : [For measuring voltage, current, and temperature with K-thermocouples or Resistance Temperature Detectors]
Temperature: K/E/J/T/R, Pt100/JPt100
Voltage: DC 50mV to 50V
Current: DC 30mA
All channels isolated; scanner measuring method
POWER METER MODULE
2331-20 : For single circuit power measurement.
Single-phase 2-wire to 3-phase 4-wire
Voltage: AC 100/200V (70 to 130VAC/140 to 260VAC)
Current: AC 5A (with CLAMP ON SENSOR 9765 or 9695-02), AC 50A (with 9695-02) ,AC 100A (with 9695-03 or 9661-01),AC 500A (with 9661-01)
POWER METER MODULE
2332-20 : For multiple circuit power measurement: from 6 circuits of single-phase 2-wire to 3 circuits of 3-phase 3-wire installations
Voltage: AC200V (100V accepted at 200V range) (70 to 260VAC)
Current: AC 5A (with CLAMP ON SENSOR 9765 or 9695-02), AC 50A (with 9695-02), AC 100A (with 9695-03 or 9661-01), AC 500A (with 9661-01)
*3-phase 4-wire circuit cannot be measured
INPUT MODULE
2341-20 : For recording the status of contact/voltage signals
8ch input, easily capture on/off status with LED
OUTPUT MODULE
2342-20 : Outputs control signal according to commands from above or based on measurement module data; 8ch output (open corrector)
RS LINK MODULE
2343-20 : For communicating with RS-232C interface equipped instruments
Interface: RS-232C, Transfer speed: 57.6kbps(max.)
Please inquire regarding compatible instruments.
(Existing compatible HIOKI instruments include Models 3331 and 3332.)
AIR MODULE
2351-20 : 2.4GHz band SS wireless technology(RS-232Cequipped)
Transfer speed: 51.9kbps(fixed), RS-232C: 57.6kbps(max.)
*Note: Requires modification according to regional or national standards. Contact HIOKI for more information.
WIRE MODULE
2352-20 : For small-scale measurement systems or built-in use
Interface: RS-232C, Transfer speed: 57.6kbps(max.)
LAN MODULE
2353-20 : For data logging via LAN
Interface: 10BASE-T
MEMORY MODULE
2354 : Store measurement data to the Compact Flash card or transfer data to a PC via LAN (100BASE-TX) , FTP Server Function
AC POWER MODULE
2361-20 : Power supply for the communication modules and measurement modules (max. 10 modules)
Input: AC 100 to 240V, Output: DC5V/2.4A
DC POWER MODULE
2362-20 : Power supply for the communication modules and measurement modules (max 10 modules)
Input: DC 19 to 36V, Output: DC5V / 2.4A
MODULE BASE
2391 : Series For connecting modules (3 slots reserved for power supply and communication module)
2391-01: For relay and master station
2391-02: 5 measurement module slots
2391-03: 10 measurement module slots
*Model 2331-20 uses 2 slots
MODULE BASE
2392 : Series For connecting modules (also connects with additional module bases for increased measurement capabilities)
2392-01 : 1 slot; includes power and internal bus connection terminal
2392-02*: 2 slot; connect with 2391-21 for additional measurement modules
* POWER MODULE not compatible; must use with Model 2392-21 to access POWER MODULE