Welcome to
Nanjing Conpo Power Tech. Co., Ltd

Free Member
Nanjing Conpo Power Tech. Co.,  Ltd
Nanjing Conpo Power Tech. Co., Ltd
China
  • Products Catalog

    HJR Series Intelligent Motor Soft Starter

    HJR Series Intelligent Motor Soft Starter

    Quantity Order:
    Origin:
    China
    Pack. & Delivery:
    Standard export packing

    Specification :

    Feature
    HJR serie motor soft starter adopts intelligent digital control t ocarry out automatic control on the motor by using mono chip computer as the intelligent center and the controllable silicon module as the executing component. It is to be applied squirrel cage asynchronous motor control with various loads and helps the motro to start smoothly under any operation conditions, so that it protects the drag system reduce the impact on the powr network inposed by the starting current and ensure the reliable starting of the motor. It also helps the motor to stop running smoothly with a reduced speed and the function of soft stopping can slove effectively the surging problem of inertia system when stopping. The conventinal motor staring equipments can not realize it and eliminate the anti-inertial impact of the system operation life, to reduce system construction price and to improve system reliability. It is compatible with various of all starting equipments and is the idealist new generation of starters and self-coupling reduced voltage starters.

    Specification:

    Type:
    HJR205.5~ 2090
    HJR2100~ 2600 5.5
    KW 7.5
    KW 11.5
    KW 15
    KW 18.5
    KW 22
    KW 30
    KW 37
    KW 45
    KW 55
    KW 75
    KW 90
    KW 100
    KW 132
    KW 160
    KW 200
    KW 250
    KW 280
    KW 320
    KW 400
    KW 500
    KW 600
    KW
    Input voltage Three-phase 380V-15% ~ 415+ 10%
    Frequency 50/ 60Hz
    Adaptive motor Squirrel-cage three-phase asynchronous motor
    Starting times It is recommended not to exceed 20 times per hour
    Control modes 1) . Operation panel control; 2) Operation panel + external control; 3) External control; 4) External control + COM control;
    5) Operation panel + External+ COM control; 6) Operational panel + COM control; 7) . COM control; 8) No start or stop operation
    Start modes 1) .Current-limiting start; 2) . Voltage ramp start; 3) . Kickstart+ current-limiting start; 4) . Kickstart + voltage ramp start;
    5) . Current ramp start; 6) . Voltage current-limiting double closed-loopstart
    Stop modes Soft stop; 2) . Free stop
    Protective functions 1) . Open loop protection for external instantaneous stop terminals; 2) . Over-heat protector for soft starter; 3) . Protection for too long starting time;
    4) . Input open phase protection; 5) . Output open-phase protection; 6) Unbalanced three-phase protection; 7) . Starting over current protection;
    8) . Running over load protection; 9) . Under voltage protection for power voltage; 10) . Over voltage protection for power voltage;
    11) . Protection for fault parameter setting; 12) . Load short circuit protection; 13) . Auto-restart or incorrect wiring protection; 14) . Incorrect wiring protection of external control stop terminals
    Ambient Place to be used Indoor location with good ventilation free from corrosive gas and conductive dust
    Altitude Below 1000M. Operating should be perform before use if the altitude is higher than 1000M.
    Ambient temperature -10~ + 40º C
    Ambient humidity d90% RH without dew condensation
    Vibration



You have [3] new inquiries.
Go to Member Menu

Home - Trade List - Product List - Inquiry List - Cooperation List - Company List
Copyright © 2024 Indomonster.com. All Rights Reserved.