    On-Line UPS C1K/ 2K/ 3K, C1KS/ 2KS/ 3KS

    Quantity Order:
    Origin:
    China
    Payment Method:
    Telegraphic Transfer (T/T)
    Pack. & Delivery:
    Standard export packing

    Specification :

    Feature:
    1. True on-line double conversion technology with advantage microprocessor control
    2. Wide input voltage range
    3. Zero transfer time
    4. Prottection against all type of power problems
    5. Self test while start of the UPS
    6. Site wiring fault warning
    7. On-battery power-on function
    8. Smart RS232 communication interface
    9. Intelligent slot available
    10. Sealed lead-acid, maintenance free battery

    Application:
    Servers, Data-center, Critical network devices, Sensitive electric equipment, Telecom.

    Model C1K C2K C3K C1KS C2KS C3KS
    Capacity VA/ W 1KVA/ 0.7KW 2KVA/ 1.4KW 3KVA/ 2.1KW 1KVA/ 0.7KW 2KVA/ 1.4KW 3KVA/ 2.1KW
    Input Nominal voltage 110/ 115/ 120VAC or 220/ 230/ 240VAC
    Voltage range 180~ 300VAC
    Frequency range 50Hz: 46~ 54Hz; 60Hz: 56~ 64Hz
    Phase Single phase
    Power factor > 97%
    Connection IEC320-10A IEC320-10A IEC320-16A IEC320-10A IEC320-10A IEC320-16A
    Output Voltage 110/ 115/ 120VAC x( 1+ / -2% ) or 220/ 230/ 240VAC x( 1+ / -2% )
    Frequency Synchronization range( line mode) ; 50 or 60 x( 1+ / -0.2% ) Hz ( Battery mode)
    Phase Single phase
    Wave form Sine wave
    Power factor 0.7
    Voltage distortion 3% 4% 4% 3% 4% 4%
    Overload capability 110% -150% for 30sec. e 150% for 200ms
    Current crest ratio 3: 1
    Connections IEC320* 4 IEC320* 6 IEC320* 3 IEC320* 4 IEC320* 6 IEC320* 3
    Battery Type Sealed, maintenance free, lead-acid
    Nominal
    DC voltage 36VDC 96VDC 96VDC
    Quantity 3pcs 8pcs 8pcs Depends on the requested back-up time
    Back-up time( full load) 5min 9min 5min Depends on the capacity of the external battery bank
    Recharge time 5hrs to 90% if capacity Depends on the capacity of the external battery bank
    Automatic transfer On overload and UPS failure
    Before UPS
    power on Default â ONâ user adjustable to â YESâ
    Voltage range 40~ 132VAC( default) , user adjustable within 40~ 143VAC or 80~ 264VA( default) , user adjustable within 80~ 286VAC
    Transfer time AC to DC
    zero Inverter to bypass 4ms( typical)
    Indicator LED display Load level/ Battery level, Battery, Utility power, Inverter, Bypass, Overload, Fault
    LCD display UPS status 1/ P 0/ P voltage frequency, Battery voltage, Battery capacity, loading, Temperature, History record
    Audible alarm Bypass, On battery mode, Battery low, Overload, Fault etc
    Acoustic noise At 1meter
    distance < 45dB < 50dB < 50dB < 45dB < 50dB < 50dB
    Communications DB-9 port RS-232 series interface
    Intelligent slot Options: SMNP card, AS400 card or winpower CMC/ ( USB port)
    Environment Operating
    Tem. 0~ 40º C
    Operating Humidity 20~ 90% non-condensing
    Weight Net( kg) 13 31.5 32 7 13.5 14
    Dimensions( pkg) WxDxH
    ( mm) 240* 495* 335 335* 590* 480 335* 590* 480 240* 495* 335 335* 590* 480 335* 590* 480



You have [3] new inquiries.