Welcome to Indomonster.com
Sign In | Sign Up
Priority Member Indomonster Priority15th Year
CV. ANDALAN PRIMA SEJAHTERA ( andalan_ prima@ yahoo.com)
http://indomonster.com/andalanprimasejahter/
`CV. ANDALAN PRIMA SEJAHTERA, Telpon: + 62-21-29253184, 021-29253187, 46560833, 46560834, Fak: 021-29253186 Email : support@andalanprimasejahtera.com
Contact Information
Name:

Mr. Enangkholis / Heru [Director/CEO/General Manager]

E-mail:
Instant Messaging:

ICQ: andalanprimasejahtera
Google Talk:  www.andalaninstrument.com  www.andalaninstrument.com
Y!: edy_girsangta@yahoo.com 
Phone Number:

Phone number of Mr. Enangkholis  / Heru at bekasi utara - Indonesia

Mobile Number:

Mobile number of Mr. Enangkholis  / Heru at bekasi utara - Indonesia

Fax Number:

Fax number of Mr. Enangkholis  / Heru at bekasi utara - Indonesia

Address:

Jl. Muhtar Tabrani Perum Bintang Metropol Blok A-7/16
bekasi utara - Indonesia 17122
Indonesia

Valid Address

http: / / www.andalaninstrument.com
Average User Review

There is no review for this company

Write a review
Language :

Products Catalog

HACH 2100Q Portable Turbidimeter[Jun. 30, 2010 23:02:21]
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
OriginUnited States

Specification

Meets EPA Method 180.1

• Single-standard RapidCalTM calibration offers the simplest solution for low-level measurements.
• Single-step verification and on-screen assisted calibration eliminates the need to reference complicated manuals.
• Exclusive algorithm in the Rapidly Settling TurbidityTM mode provides accurate, repeatable measurements for rapidly settling, difficult-to-measure samples while eliminating the need for redundant measurements and estimating.
Hach portable turbidimeters are supplied with four AA alkaline batteries, a carrying case with insert, StablCal primary calibration standards in 1" sealed vials ( 20, 100, 800 NTU) , a 10 NTU primary verification standard, 6 sample cells with screw-tops, instrument manual ( printed and on CD-ROM) , quick start guide, silicone oil and oiling cloth.

2100Q Portable Turbidimeter

Specifications

Measurement Method Ratio turbidimetric determination using a primary nephelometric light
scatter signal ( 90° ) to the transmitted light scatter signal
Regulatory Meets EPA Method 180.1
Lamp Source Tungsten filament lamp
Range 0-1000 NTU
Accuracy ± 2% of reading plus stray light from 0-1000 NTU
Repeatability ± 1% of reading or 0.01 NTU, whichever is greater
Resolution 0.01 NTU on lowest range
Stray Light = 0.02 NTU
Signal Averaging Selectable on or off
Detector Silicon Photodiode
Reading Modes Normal ( Push to Read)
Signal Averaging
Rapidly Settling Turbidity( TM)
Calibration Options Single step RapidCal( TM) for low-level regulatory reporting from 0-40 NTU
Full range calibration from 0-1000 NTU
Calibration to degrees of turbidity
Calibration Logger Records the last 25 successful calibrations
Verification Logger Logs the last 250 successful verifications
Data Logger 500 records
Power Requirement AC 100-240 V, 50/ 60 Hz ( with optional Power or USB+ Power Module)
4 AA alkaline batteries
Rechargeable NiMH ( with optional USB+ Power Module)
Operating Conditions Temperature: 0 to 50 ° C ( 32 to 122 ° F)
Relative Humidity: 0-90% at 30 ° C, 0-80% at 40 ° C, 0-70% at 50 ° C noncondensing
Storage Conditions -40 to 60 ° C ( -40 to 140 ° F) , instrument only
Interface Optional USB
Sample Required 15 mL ( 0.5 oz.)
Sample Cells Round cells, 60 x 25 mm ( 2.36 x 1 in.) , borosilicate glass with screw caps
Dimensions 22.9 x 10.7 x 7.7 cm ( 9.0 x 4.2 x 3.0 in.)
Weight 530 g ( 1.17 lb) without batteries
620 g ( 1.37 lb) with four AA alkaline batteries
Meter Enclosure Rating IP67 ( closed lid, battery and module compartment excluded)
Protection Class Power supply: Class II
Certification CE certified
Warranty 1 year