Welcome to
SOLARIS-NEWTECH, INC.

Free Member
SOLARIS-NEWTECH, INC.
China
  • Sell

    NT2C Desktop/Portable Vital Signs Monitor with Large LED Display and Optional Internal Thermal Recorder

    Quantity Order:
    Payment Method:
    Telegraphic Transfer (T/T)
    Quantity:
    min.1pc
    Pack. & Delivery:
    standard
    NT2C: Desktop/Portable Vital Signs Monitors

    Bright, Easy-to-Read Large LED Display
    Durable, Compact and Lightweight
    Long-life Internal Rechargeable Battery for Uninterrupted Monitoring
    Accurate, Reliable Readings During Low Perfusion and Montion
    Audible/Visual Three Level Alarms with Alarm Volume Control
    72-hour Data Memory Allowing On-screen Data Replay
    Suitable for Adult, Pediatric and Neonate
    Optional Internal Thermal Recorder
    Able to Connect to Nurse Call Network

    Product Features :

    SpO2 Accuracy
    No Motion:
    Adults, Pediatrics: 70~100% ¡Ã2%
    0~69% unspecified
    Neonates: 70~100% ¡Ã3%
    0~69% unspecified
    With Motion:
    Adults, Pediatrics: 70~100% ¡Ã3%
    0~69% unspecified
    Neonates: 70~100% ¡Ã4%
    0~69% unspecified
    Low Perfusion:
    Adults, Pediatrics: 70~100% ¡Ã3%
    0~69% unspecified
    Neonates: 70~100% ¡Ã4%
    0~69% unspecified

    Pulse Rate Accuracy
    No Motion:
    Adults, Pediatrics, Neonates: ¡Ã3%
    With Motion:
    Adults, Pediatrics, Neonates: ¡Ã5%
    Low Perfusion:
    Adults, Pediatrics, Neonates: ¡Ã5%

    Non-Invasive Blood Pressure
    Measurement type:
    Adult, Pediatric, Neonatal
    Measurement range:
    Adult:
    Systolic 40bpm~270mmHg
    Diastolic 20bpm~200mmHg
    Mean 30bpm~220mmHg
    Pediatric:
    Systolic 40bpm~180mmHg
    Diastolic 15bpm~160mmHg
    Mean 20bpm~170mmHg
    Neonatal:
    Systolic 30bpm~140mmHg
    Diastolic 15bpm~100mmHg
    Mean 20bpm~115mmHg
    Accuracy: ¡Ã3mmHg or 2%(choice max)
    Resolution: 1mmHg
    Protection: over pressure

    Performance Measurement Range
    SpO2:0¡«100%
    Pulse Rate: 30bpm~250bpm

    Alarm
    Audible/Visual Alarms
    Adjustable Alarm Limits

    Temperature
    Measurement range: 25¡«45¡æ
    Accuracy: ¡Ã0.2¡æ

    Output
    RS-232 Serial Port for Digital Output
    Nurse Call Function

    Electrical Instrument
    Power Requirements:
    100~240VAC, 50/60Hz, 20VA
    Fuse Rating: 1.0A

    Battery
    Internal Battery: 12V ¡¡
    Battery Capacity: ¡à 24 hours

    Environment
    Opreation Temperature: 5¡«40¡æ
    41~104¨H
    Humidity: 10~95%
    Transport/Storage Temperature:
    -20¡«+70¡æ (-4¨H~158¨H)
    Humidity: 10~95%

    Physical Characteristics
    Dimensions:
    264mm(W) x 95mm(H) x 172mm(D)
    [10.39in(W) x 3.74in(H) x 6.77in(D)
    Net Weight: 2.25kg/5ib

    Compliance
    EN60601-1/ GB9706.1
    EN60601-1-2, EN60601-2-49

    One adult finger SpO2 sensor is included with each unit