Specification :
1. An overview
Electromagnetic flow meter is designed specifically for the water industry to meet the city' s water supply to ensure the accurate calculation, the scene is widely used in places without power supply, such as urban water supply, sewage treatment, water conservancy and other industries.
Electromagnetic flow meter specially designed sensor excitation system, and high-performance lithium battery-powered systems, and uses 16-bit AMD embedded processor power, with all-digital signal processing, measurement stability, high measurement accuracy, anti - Interference ability, and other features, automatic bi-directional flow measurement, on-site instantaneous flow of positive and negative cumulative total to show that self-diagnosis alarm FAULT Far GSM wireless data functions, the user through the powerful GSM / GPRS remote management software system can flow Far total wireless data storage functions.
2. The main technical parameters
 Diameter: DN10-DN1200 DN150- DN3000( Also optional plug-in battery-powered electromagnetic flow meter)
 Pressure: 0.6^ 4.0Mpa( Special pressure customizable)
 Precision: ± 0.5% ± 1.0%
 measuring range: 0 ~ 12m / s
 Media Measurement ( conductivity) : > 20¼ s/ cm
 medium temperature: -10 ~ 100
 ambient temperature: -10 ~ 60
 humidity environment: d 95% ( relative humidity)
 power supply: 3.6V/ DC built-in lithium battery-powered, continuous working hours, more than 5 years
 electrode materials: 316L stainless steel, HC, HB, titanium, tantalum, platinum / iridium alloy
 lining materials: poly chloroprene rubber, polyurethane rubber, PTFE, F46, PFA
 connections: flange type, plug-in, clip -
 structure in the form of: a body divided body
 level of protection: IP68
 display: LCD large-screen liquid crystal display instantaneous flow of positive / reverse the cumulative total and prompt warning
 output: the output pulse 0.0001-10m / p pulse width can be set to 20ms ( passive output optocoupler)
 means of communication: GSM wireless data transmission ( packet in the form of text messages)
3. Appearance and size of the installation
Appearance and size of the installation ( type flange connection) Figure 1, Table 1
Figure 1
Table 1
Diameter
mm size of the installation Pressure 1.6Mpa
H L n ¦ d ¦ D D2
10 290 140 4 14 90 60
15 293 200 4 14 95 65
20 301 200 4 14 105 75
25 306 200 4 14 115 85
32 325 200 4 18 140 100
40 335 200 4 18 150 110
50 350 200 4 18 165 125
65 375 250 4 18 185 145
80 385 250 8 18 200 160
100 405 250 8 18 220 180
125 435 300 8 18 250 210
150 470 300 8 22 285 240
200 525 350 12 22 340 295
250 590 450 12 26 405 355
300 645 500 12 26 460 410
350 705 550 16 26 520 470
400 765 600 16 30 580 525
450 825 600 20 30 640 585
500 900 600 20 33 715 650
600 1025 600 20 36 840 770
700 1080 700 24 30 895 840
800 1200 800 24 33 1015 950
900 1300 900 28 33 1115 1050
1000 1415 1000 28 36 1230 1160
1200 1590 1200 32 36 1405 1340
4. Display
The instrument for large LCD screen LCD, two-line display, scheduled for the last 10 cumulative flow shows that the greatest value 9, 999, 999, 999 display can be displayed alternate is, the reverse flow of the cumulative value of the schedule for the next five instantaneous flow shows that the largest display 99999 value can be displayed alternate is, the reverse flow of transient value and prompt report to the police.
Alarm Information Corrective measures.
Air Traffic Alarm Check whether the pipeline is full of fluid under test, to adjust air traffic control warning
Threshold adjustment factor and the air traffic control
Magnetically-shielded alarm system circuit Check excitation output signal cable wiring and sensors
Alarm signal output short-circuit Check signal cable wiring and sensor input
Check whether the appropriate scope of the range set to re-set range.
Limit traffic police Check the output pulse frequency settings are appropriate, pulse frequency output
Pulse output limit alarm Shall not exceed the maximum 1000HZ, re-set the maximum frequency
Check signal cable wiring and sensor input
Check whether the appropriate scope of the range set to re-set range.
Low-voltage battery alarm Battery replacement
GSM forced to send police GSM mandatory testing the use