Specification :
The Control Unit
The ECOLINE control unit with microcontroller
technology enables the barrier to be operated
manually or automatically. There are 11
standard functions to be selected. The barrier
either closes by the manual pulse command
CLOSE, automatically after passage or in dependence
on the connected safety equipment.
The electronic braking guarantees optimum
braking of the boom without bouncing or
swinging out in the end positions.
Besides the standard operating modes several
special functions are additionally integrated.
These enable the drive of warning lights
and signal lamps. The storage of the activated
opening pulses makes possible an
automatic operation, i.e. the barrier remains
open until all vehicles have passed. In case of
power failure can be selected if the barrier
shall start either after a manual reset, a signal
reset or automatically. For safety reasons the
manual reset function is factory-set. This
means the barrier remains open as long as
the reset button at the control unit is pressed
manually. The electrical connection is carried
out via the big and clear terminals for mains
supply and control power. The motor is
driven abrasion-free via TRIAC output stage.
All signal inputs and relay outputs are optodecoupled.
Simple adjustment of the operating
mode and selection of the special
functions by means of a rotary switch and
DIP-switch.
For the power supply of external devices, e.g.
induction loop detectors 24 V DC / 0.5 A will
be supplied.