DS 201L AC / A - C: RCBO Type AC / A - C curve Standards: IEC / EN 61 009 Function: single phase circuit protection against fault current to ground, shaped ( AC sinusoidal) current overload and....
PT Gema industrial is a company trading the developing , established in 2001 and was preceded by a repair service machine manufacture .The passing of time our company is the producer of the spare....
DS 201L AC / A - C: RCBO Type AC / A - C curve Standards: IEC / EN 61 009 Function: single phase circuit protection against ground fault current form ( AC sinusoidal) current overload and short....
F 200 AC: compact RCCB type AC Standards: IEC / EN 61 008 Function: protection of fault current to ground. ( AC sinusoidal) protection of indirect touch and direct touch ( dg I? n = 30 mA) ....
Auxiliary contacts S 800-AUX serves to indicate the position of contact on the MCB
S2C-BP tripping device is used for MCBs S 200 and DS 200 ( mounted on the right side) is used to automatically trip when a panel or panel door is opened.
To build an automatic source switch with ATS021 / ATS022 for two Emax circuit breakers, it is necessary accessories to be installed in the circuit breaker. Additional accessories for the ATS....
serves to transform MCB S 200 and F 200 standard into a type of plug-in base
Mounted on RCCB F 200, possible RCCB closes automatically when the RCCB trip was not caused by leakage current disruption
MCB: Compact S800PV Standards: IEC 60947-2 Breaking capacity ( Icu) : 5 kA Operating voltage: 2-pole: DC 800V ( 10 s / d 80A) ; DC 600V ( 100 s / d 125A) 3-pole: 1200V DC ( 10 s / d 80A) ; DC....
MCB: Compact S800S-C Standards: IEC Breaking capacity ( Icn) : IEC 60 898: 25 kA Breaking capacity ( Icu) : IEC 60947-2: 50 kA Function: protection and control circuits ( cables) against current....
MCB: Compact S800C-C Standards: IEC Breaking capacity ( Icn) : IEC 60 898: 15 kA Breaking capacity ( Icu) : IEC 60947-2: 25 kA Function: protection and control circuits ( cables) against current....
MCB: Compact S800N-C Standards: IEC Breaking capacity ( Icn) : IEC 60 898: 20 kA Breaking capacity ( Icu) : IEC 60947-2: 36 kA Function: protection and control circuits ( cables) against current....
MCB: S800B-C Standards: IEC 60947-2 Breaking capacity ( Icu) : 16 kA Function: protection and control circuits ( cables) against current overload and the short-circuit current is designed to meet....
MCB: S800B-K Standards: IEC 60947-2 Breaking capacity ( Icu) : 16 kA Function: protection and control circuits ( cables) against current overload and the short-circuit current is designed to meet....
MCB: Compact S 200 M UC - K  Standards: IEC 60947-2  Breaking capacity ( Icu) : 10 kA  Function: protection and control circuits such as the motor to the load current  More and short....