Environmental Specifications Diameter of measurable conductor 0.177 or 4.5 mm max Operating temperature -10 to 50 C Storage Temperature -25 to 60 C Operating Humidity < 90% @ < 30....
CAN ELECTRONIC INDONESIA We are trading company established in Jakarta. Especially " Instrument Measuring Electronic Test & Tools Education / Industry / Enviroment Equipment " CAN ELECTRONIC....
Specifications Diameter of measurable conductor 0.177 or 4.5 mm max Operating temperature -10 to 50 C Storage Temperature -25 to 60 C Operating Humidity < 90% @ < 30 C, < 75% @ ....
Specifications Temperature -20 C to 60 C ( -4 F to 140 F) Temperature accuracy 0 C to 45 C ( 0.5 C) -20 C to 0 C & 45 C to 60 C ( 1.0 C) 32 F to 113 F ( 1....
Technical Specifications Voltage range 40-700 V Frequency range 15-400 Hz Operating timer Continuous Environmental Specifications Operating temperature 0 C to 40 C Dust/ water....
Insulation resistance measurement Test voltage ( dc) Range ( dc) Accuracy ( reading) 250 V 50 G unspecified 5 % 20 % unspecified 500 V 200 k 200 k to 10 G 10 G to....
Specifications Voltage DC Maximum Voltage: 1000 V Accuracy: 1577: ( 0.2% + 2) 1587: ( 0.09% + 2) Maximum Resolution: 0.001V Voltage AC Maximum Voltage: 1000 V Accuracy: 1577: ....
AC/ DC Voltage Measurement Accuracy Range 600.0 V Resolution 0.1 V 50 Hz to 400 Hz ( % of Rdg + Digits) ( 2 % + 3) Input impedance 3 M ( nominal) , 60 dB at dc, 50 or 60 Hz ....
Technical Specifications Voltage measurement range Transmitter: 12 V, 50 V, 120 V, 230 V, 400 V Frequency range Transmitter: 0...60 Hz Output signal Transmitter: 125 kHz Voltage ....
Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for A input 11 A, 1000 V FAST Fuse ( ....
Specifications Voltage DC 175 - Accuracy* ( 0.15% + 2) 177 - Accuracy* ( 0.09% + 2) 179 - Accuracy* ( 0.09% + 2) Max. Resolution 0.1 mV Maximum 1000 V Voltage AC Accuracy* ....
Specifications Voltage DC Maximum Voltage : 1000V Accuracy: Fluke 83 V: ( 0.1% + 1) Fluke 87V: ( 0.05% + 1) Maximum Resolution: Fluke 83 V: 100 V Fluke 87 V: 10 V Voltage AC ....
Temperature Temperature measurement range -10 C to + 250 C ( 14 F to 482 F) Temperature measurement accuracy 2 C or 2% of reading in C, whichever is the greater ( at 25 ....
Specifications Diameter of measurable conductor 01.3 or 34 mm max Operating temperature -14 to 122 F ( -10 to 50 C) Storage Temperature -40 to 140 F ( -40 to 60 C) Operating....
Specifications Diameter of measurable conductor 0.12 or 30.5 mm max Operating temperature -14 to 122 F ( -10 to 50 C) Storage Temperature -40 to 140 F ( -40 to 60 C) Operating....