DRYNG OVEN LABORATORIES FINCO INC. OV - SERIES DRYNG OVEN LABORATORIES It is applicable for drying, cure, melting and sterilization in industrial and mining enterprises, laboratories and scientific....
We are a laboratories and chemicals supplier in Surabaya : Glassware; Chemicals; Water test kit ( pH meter, conductivity meter, DO meter, turbidity meter, thermometer, TDS meter, Photometer, Chlorine....
WATERBATH DIGITAL DISPLAY Finco Inc. Waterbaths Specification: Model FDW-11 FDW-12 FDW-14 FDW-16 FDW-24 FDW-26 F DW-28 Voltage 220V 50Hz Consumption Power 300W 500W 1000W 1500W 1000W 1500W 2000W....
* Analyzes 9 parameters - pH, ORP( EH) , mV, Conductivity, Total Dissolve Solids, Salinity, Resistivity, DO ( % , mg/ L, & ppm) and temperature. * Accurate 3 point pH calibration process with buffer....
Includes bottle of electrolyte, 1 sanding disc, and 6 screw-on cap membranes. 1.25 mL PE membranes. Yellow cap. Response Time ( T95 - from 0 to 100% ) = 8 seconds Flow Dependence After 4 Minutes = ....
* ACCURATE DISSOLVED OXYGEN MEASUREMENT ! SALINITY AND BAROMETRIC PRESSURE COMPENSATION ! * STORES AND RECALLS 99 DATA WITH TEMPERATURE READINGS ! * REAL TIME CLOCK FOR EACH MEMORY DATA ! * ....
Range 1999 ppm ( mg/ L) Resolution 1 ppm ( mg/ L) Accuracy  ± 2% F.S. TDS Factor 0.65 Calibration Solution HI 70442 Calibration manual, 1 point Probe HI 73301 ....
Specifications: TDS Range: 0 to 9.99ppm* ; 10.0 ppm to 99.9 ppm; 100 ppm to 999 ppm; 1.00 ppt to 99.9 ppt * Max. 199.9 ppt ( depending on factor setting) Resolution & Accuracy: 0.01, 0.1, 1 ppm ....
Specifications: Conductivity Range: 0 to 199.9 mS/ cm TDS Range: 0 to 99.9 ppt Resolution & Accuracy: 0.05% Full Scale & Temp Range: -10.0 to 110.0 Â ° C ( Meter) Resolution & Accuracy: 0.1 Â ° ....
Specifications: Range: 0 to 10.00 ppt Resolution: 0.1 ppt Accuracy: Â ± 1 % full scale ( Â ± 2 % above 5 ppt) Calibration points: 1 ( digital, push-button) ATC: Yes TDS Factor: 0.4 to 1.0 ( ....
Specifications: Range 1999  µ S/ cm Resolution 1  µ S/ cm Accuracy  ± 2% F.S. Calibration Solution HI 70031 Calibration manual, 1 point Probe HI 73303 Temperature....
Range: 0.0 to 14.0 pH Resolution: 0.1 pH Accuracy: Â ± 0.1 pH Calibration: manual, 2 points Battery Type / Life: 1.5V ( 4) / approximately 700 hours of continuous use Environment: 0 to 50Â ° C ( ....
Model : CD-4303 * -P circuit, LCD with display unit. * Max., Min., Memory recall button. * 200uS/ 2mS/ 20mS, ATC, Cell adj. * Size : 180 x 72 x 32 mm.
Conductivity Range: 0 to 199.9 mS/ cm Resolution & Accuracy: 0.05% full scale & Â ± 1% full scale + 1 LSD Calibration Points: 4 ( 1 per range) auto; 5 ( 1 per range) manual Temperature Range: 0 to....
Specifications: Range: 0 to 1990 uS/ cm Resolution: 0.1 mS/ cm Accuracy: Â ± 1 % full scale ( Â ± 2 % above 10 mS/ cm) Calibration points: 1 ( digital, push-button) ATC: Yes Non-Volatile....
Model : PH-221 * 0 to 14.00 pH, 1, 999 mV. * LCD show both pH and the temperature. * ATC or manual TEMP. compensation. * Auto calibration for pH 4, pH 7 and pH 10. * Optional pH electrode and....