Welcome!
Join Now
|
Member Sign In
Member Menu
|
Help
|
0
ALL
PRODUCT
SELL
INQUIRY
COMPANY
Recommend Indomonster.com to a friend
*
means required information
*
Your Name:
*
Your Email:
*
Your Friend's Email: :
To send to more than one person, separate addresses with a comma.
Example: name1@domain.com, name2@domain.com etc.
*
Comment:
Hi, I am Businessman I found this sample from https://www.indomonster.com and think it might be useful to you. ------------------------------------------------------- STANHOPE SETA, Setaflash Series 8 Closed Cup Flash Point Tester ( High temperature) Setaflash Series 8 Closed Cup Flash Point Tester ( High temperature) Part Number 82000-0 The Setaflash Series 8 is an automated closed cup flash point tester with a temperature range of ambient + 5 to 300° C ( ambient + 9 to 572° F) . The instrument uses an electric hot wire ignitor ( gas flame option) . There are two modes of flash point operation; Flash/ No Flash and Ramp. The ramp mode increases the sample temperature at a rate of 2° C/ min, allowing determination of a flash point in accordance with ASTM D7236 and IP 534. The dipping sequence occurs automatically every 1° C up to 100° C ( every 2° C rise above 100° C) , until either a flash is detected or the end of test temperature is reached. The ignitor uses a new electrical hotwire ( a gas flame option is available) . The bright colour LCD display shows test parameters and the flash point result. The text and colour of top line of the display indicates the instrument status. All functions are accessed via menus, navigated by the keypad. Audible prompts are given when an action is required from the operator. The automatic flash point detection system is tuned to ignore halo and other false flash effects, reducing the chance of misinterpretation of the test result, and enhancing repeatability. Barometric pressure is measured by an internal barometer, and the correction is automatically applied to the test result. At the end of a flash point test, the sample cup is cooled by forced air to reduce the cycle time between tests. Up to 64 results can be stored in memory, tagged with operator and sample references, and can be downloaded to a PC or printer via the RS232C port ( USB or LAN ports available as options) . The firmware is upgradeable for future developments. SUPPLIED WITH: Ignitor, 2ml syringe, mains lead and instruction manual. SPECIFICATIONS Temperature Range Ambient + 5 to 300° C ( Ambient + 9 to 572° F) Sample Size 2 or 4ml according to method Ignitor Electrical Hot Wire ( optional Gas Flame) Test duration, Rapid Equilibrium Mode 1 minute below 100° C, 2 minutes above 100° C, Test duration, Ramp Mode Typically 7 minutes Sample Cup Material Aluminium Heating / Cooling Method Ceramic Pad, Forced Air ( post-test cooldown) Voltage 100 to 250V, 50/ 60Hz ( 2x AA dry cell batteries required for internal clock) Power 300W ( maximum) Size ( HxWxD) 30 x 34 x 38cm Weight 8kg For detailed information, please go to http://www.indomonster.com/karuniamakmur/2399939
0.0067 194.163.150.105