Specification :
ARIES 2800
Special Feature
Application: Adult, Pediatric
Driven mode: Pneumatically driven electronically controlled
Mode: Semi-open, Semi-closed or closed system
Anesthetic vaporizer: One vaporizer
Anesthesia Ventilator
Display: High light LED display
Ventilation mode: IPPV and Manual mode
Tidal Volume: 50 ~ 1600ml
Breath frequency: 1 ~ 90BPM
I: E ratio: 4: 1 ~ 1: 6
Monitor parameter: Tidal volume, breath frequency, MV, Airway pressure
Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm
Main Unit
Circle absorber: Compact circle absorber
Bellow: 50 ~ 1600ml
Oxygen FLUSH: 25L/ min ~ 75L/ min
Flow meter:
O2, N2O two-tube flowmeter
O2 tube: 0L/ min ~ 10L/ min
N2O tube: 0L/ min ~ 10L/ min
O2 and N2O linkage device
Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% )
Gas source pressure
O2: 0.25 ~ 0.65Mpa
N2O: 0.25~ 0.65Mpa
Gauge: 2 units, one N2O, one O2
ARIES 2800A
Special Feature
Application: Adult, Pediatric
Driven mode: Pneumatically driven electronically controlled
Mode: Semi-open, Semi-closed or closed system
Anesthetic vaporizer: One vaporizer
Anesthesia Ventilator
Display: High light LED display
Ventilation mode: IPPV and Manual mode
Tidal Volume: 50 ~ 1600ml
Breath frequency: 1 ~ 90BPM
I: E ratio: 4: 1 ~ 1: 6
Monitor parameter: Tidal volume, breath frequency, MV, Airway pressure
Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm
Main Unit
Circle absorber: Compact circle absorber
Bellow: 50 ~ 1600ml
Oxygen FLUSH: 25L/ min ~ 75L/ min
Flow meter:
O2 two-tube flowmeter
O2 tube: 0L/ min ~ 1L/ min ~ 10L/ min
Gas source pressure
O2: 0.25 ~ 0.65Mpa
Gauge: 1 unit, O2