Specification :
Power Cables
Description:
Power cable Product Description Rated voltage: 0.6/ 1KV, 6.6KV, 11KV, 22KV, 36KV, 110KV Conductor: Solid copper, Stranded copper or Aluminum Insulation: PVC or XLPE compound Armouring: Unarmored or AWA, SWA, STA Sheath: PVC or LSOH compound Standards: GB, IEC, BS, VDE, AS/ NZS, ICEA, JIS Application: Different type can be used in power networks, underground, outdoor, and in cable ducting
Product Description
XLPE insulated power cable is used for laying indoor and outdoor, underground, vertical well and underwater, etc.
Nom. cross section mm2 Nom. insulation thickness mm Steel tape thickness mm Nom.sheath thickness mm Approx OD of cable mm Approx weight of cable kg/ km Max.DC resistance of conductor at 20C Current rating( A)
YJV
YJLV YJV22
YJLV22 YJV
YJLV YJV22
YJLV22 Direct in ground Run in air
YJV YJPV YJV22 YJLV22 Cu Al Cu Al Cu Al
4* 4+ 1* 1.5 0.7/ 0.7 - 1.8 1.8 16 19 361 235 539 424 4 .61/ 7.41 7.41/ 12.1 45 36 36 27
4* 6+ 1* 4 0.7/ 0.7 0.2 1.8 1.8 17 21 465 293 671 499 3.08/ 4.61 4.61/ 7.41 57 46 43 35
4* 10+ 1* 6 0.7/ 0.7 0.2 1.8 1.8 21 24 706 421 951 666 1.83/ 3.08 3.08/ 4.61 77 59 60 47
4* 16+ 1* 10 0.7/ 0.7 0.2 1.8 1.8 23 26 1038 578 1320 860 1.15/ 1.83 1.91/ 3.08 105 80 83 64
4* 25+ 1* 16 0.9/ 0.7 0.2 1.8 1.8 27 31 1554 834 1888 1167 0.727/ 1.15 1.20/ 1.91 125 100 105 82
4* 35+ 1 * 16 0.9/ 0.7 0.2 1.8 1.9 30 33 1999 1030 2378 1409 0.524/ 1.15 0.868/ 1.91 155 120 125 100
4* 50+ 1* 25 1.0/ 0.9 0.5 1.9 2.1 34 39 2735 1381 3558 2204 0.387/ 0. 727 0.641/ 1.20 185 145 160 125
4* 70+ 1* 35 1.1/ 0.9 0.5 2.1 2.2 39 44 3805 1886 4737 2818 0.268/ 0.524 0.443/ 0.868 225 175 200 155
4* 95+ 1* 50 1.1/ 1.0 0.5 2.2 2.4 44 49 5114 2461 6219 3566 0.193/ 0.387 0.320/ 0.641 270 210 245 200
4* 120 + 1* 70 1.2/ 1.1 0.5 2.4 2.5 49 54 6481 3088 7709 4315 0.153/ 0.268 0.253/ 0.443 310 240 285 220
More Product Features
Trademark: GHCABLE
Standard: Iec60502
Origin: Jiangsu, China
Currency: AC Cable
Voltage: Low And Medium Voltage Cable
Insulation Material: XLPE
Application: Power Station
Export Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Type Designation AYWY / AYFY
Rated Voltage 1100 V
Design Standard IS - 1554 ( Part -1) -1988
Number of Cores and Nominal Area of Conductor Thickness of insulation ( Nom) Thickness of inner sheath ( Minimum ) Armour wire diameter or steel strips Thickness of outer sheath ( minimum) Approx. Overall diameter Total weight approx. Maximum DC resistance of conductor at 20? C Approx. AC resistance at operating temp. at 70? C mm? mm mm mm mm mm Kg/ Km Ohm/ Km Ohm/ Km. 2x1.5* 0.8 0.3 1.40 1.24 13.80 400 18.1 21: 74 2x2.5* 0.9 0.3 1.40 1.24 14.80 439 12.1 14.53 2x4* 1.0 0.3 1.40 1.24 15.80 492 7.41 8.90 2x6* 1.0 0.3 1.40 1.24 17.80 573 4.61 5.54 2x10* 1.0 0.3 1.40 1.40 18.80 700 3.08 3.70 2x16 1.0 0.3 4.0x0.8 1.40 18.80 643 1.91 2.30 2x25 1.2 0.3 4.0x0.8 1.40 21.40 806 1.20 1.44 2x35 1.2 0.3 4.0x0.8 1.40 23.00 926 0.868 1.04 2x50 1.4 0.3 4.0x0.8 1.40 25.80 1119 0.641 0.770 2x70 1.4 0.3 4.0x0.8 1.40 28.20 1320 0.443 0.532 2x95 1.6 0.3 4.0x0.8 1.56 31.90 16.80 0.320 0.385 2x120 1.6 0.4 4.0x0.8 1.56 34.10 1903 0.253 0.305 2x150 1.8 0.4 4.0x0.8 1.56 37.30 2238 0.206 0.249 2x185 2.0 0.4 4.0x0.8 1.72 41.00 2646 0.164 0.199 2x240 2.2 0.5 4.0x0.8 1.88 45.40 3264 0.125 0.152 2x300 2.4 0.5 4.0x0.8 2.04 50.50 3868 0.100 0.123 2x400 2.60 0.60 4.0x0.8 2.20 55.80 4710 0.0778 0.0975
PVC Insulated, Wire / Strip Armoured and
Hot PVC Insulated, Wire / Strip Armoured and Products
Packaging & Delivery
Packaging Detail: wooden drum packing
Delivery Detail: 10 days
Specifications
NYY Power Cable CE
good quality and short time delivery
NYY Is used as a power and control cable in static installations, indoors, outdoors, underground, in concrete and in water.
The use of NYY cables is in accordance with VDE 0298 part 1. The current capacity is according to HD 603 S.1 and VDE 0276 part 1000. The product conforms to EEC directive 73 / 23 ( Low Voltage Directive) . CE.
Cable Construction
Single of multi-wire conductors of plain copper wires, PVC core insulation, cores twice concentrically according to VDE 0293, common core sheathing, outer sheath of PVC standard colour black, flame retardant.
Technical Data
Minimum bending radius for single core : 15 x outer diameter
Minimum bending radius for multi core : 12 x outer diameter
Conductor Configurations:
According to VDE 0295 / IEC 60228
re = round conductor, single wire
rm = round conductor, multi wire
sm = sectorial conductor