    Asikeco : Oil in Water Monitor

    Asikeco : Oil in Water Monitor

    Price:
    Negotiable
    Quantity Order:
    Origin:
    United States
    Payment Method:
    Telegraphic Transfer (T/T)
    Pack. & Delivery:
    Exclusive

    Specification :

    Description:

    The ability to analytically quantify oil in water is greatly enhanced with the Sample Transfer Stripper ( Patented Membrane Technology) and the solid state sensor offered by Analytical Systems International ( ASI) . The analyzer system utilizes many patented and exclusive features only available from ASI.

    The principle of operation for the Model 204 Oil in Water Analyzer requires a consistent free flowing liquid sample into a Sample Transfer Stripper unit that separates the liquids from the VOCs in the oil. A hydrocarbon free, consistently flowing air carrier then sweeps the VOC components from the oil in a gaseous form into the solid state sensor for quantitative analysis in ppb w, ppm w, or up to saturation levels. An optional patented liquid validation/ calibration by Perm Tube is available. This unattended on-line analysis is economically superior to inaccurate laboratory analyzers where unstable grab samples result in oil deterioration that produce analytical errors. Downtime is reduced to less than 10% of the El Paso, TOC or Sparger methods and the economic pay out is increased because of reduced product loss. In one case, 12, 000 pounds of product loss per day was quickly identified by this proven and accurate on-line analytical method. Patents and Patents Pending based on letters that are available on request.

    Applications include the analysis of oil in water for cooling towers, heat exchangers, holding ponds, run off water, waste water and more.

    Typical Applications:

    Bilge water discharge monitoring
    The International Maritime Organization ( IMO) and the U.S. Coast Guard ( USCG) requires all ships over 400 gross tons to monitor bilge water discharges and are limited by 15 ppm. The Canadian Coast Guard limits discharge concentration at 5 ppm.
    Oil in Wastewater
    Where the dissolved oil or hydrocarbon content could be PPBw, PPMw, or at saturation levels, Model 204 Oil in Water Analyzer easily provides continuous measurement online.
    Oil in produced water
    The Model 204 Oil in Water Monitor can continuously monitor the discharge of produced water as required by the Environmental Protection Agency ( EPA) . The EPA requires that produced water discharge must contain a concentration of less than 29 ppm oil and less than 42 ppm grease for a 30 day average and daily maximum.
    Oil in Cooling Water and Holding Ponds
    Equipment leaks, spills, and drainage run-offs can cause build-up of hydrocarbon in the water. The Model 204 can give a continuous online indication of the volatile organic carbon ( VOC) / oil contained in these waters.
    Fuels in Storm Runoff Water
    It is required by the U.S. EPA that all storm water runoff be monitored. The Model 204 can continuously detect fuel in water at a concentration 1 ppm or better, including as dissolved hydrocarbons.
    Phenol in water
    The Model 204 can continuously monitor the cooling water to detect a leak and prevent a discharge violation.

    Hydroelectric dam sumps
    Drain systems for fuel oil storage tank area
    Includes hydro-carbon storage facilities.
    Ground water recovery sites
    Includes fuel storage and transformer sites.
    Boiler condensate and power plant cooling water reclaiming systems
    Including integral oil coolers.
    Intake monitoring for Desalination plants
    Water discharge in municipal water treatment systems
    Oily water or grease discharges in excess of 15 parts per million( ppm) is not allowed or surcharged in most municipal water systems.
    Engine cooling water
    Engine damage can be caused by oil in engine cooling water.
    Effluent monitoring
    After an oil-water separator.
    Features:

    Essentially Maintenance Free
    Field Calibrations Virtually Never Required
    No Normal Consumables
    Typical 99% Uptime
    Auto-Clean System Option
    Proven On-Line Reliability
    Very Low Cost of Ownership
    Precision to 1 ppb
    Clean and Dirty Water Analysis
    On-line Continuous Analysis
    True Liquid Validation by PermTube tm
    Over 25 Years Experience
    4-20ma & RS-485
    Fast Response Time
    Explosion Proof
    TCEQ " Best Available Control Technology" & " Equivalency" Letters Exclusive
    Preferred Vendor for 204 by Shell & Saudi Aramco