Welcome to Indomonster.com
Sign In | Sign Up
PRO TEKNIK
PRO-TEKNIK
Priority Member Indomonster Priority 14th Year
PRO-TEKNIK
http://indomonster.com/pro-teknik/
Contact Information
Name:
Mr. Romeo Sinaga
[Marketing]
E-mail:

Homepage:
Instant Messaging:
Y!: pro.teknik 
Phone Number:
Phone number of Mr. Romeo Sinaga at Jakarta Timur
Mobile Number:
Mobile number of Mr. Romeo Sinaga at Jakarta Timur
Fax Number:
Fax number of Mr. Romeo Sinaga at Jakarta Timur
Address:
JL. Taruna dalam VII No.56 , Pulogadung, Indonesia
Jakarta Timur 13260, Jakarta
Indonesia
Valid Address
PRO-TEKNIK INDONESIA, Supplier & Trading CALIBER INTERNATIONAL PRODUCT
Average User Review

There is no review for this company

Write a review
Language :

Products Catalog

Jual EPAM-5000, Hub. Bp. Sinaga, email: pro.teknik@ yahoo.co.id; pro-teknik@ live.com, Tlpn/ fax: 021 470 4719, Mobile : 0815 1311 6206 ; 021 93 800 487 ; 08 2124 167 067
Pricemahal
Quantity Order:
Payment MethodTelegraphic Transfer (T/T), Cashier Order
Pack. & Deliverystandard
OriginUnited States

Specification

EPAM-5000,
Electronic Monitor for Measuring EPA PM Criteria

The HAZ-DUST EPAM-5000 is a portable microprocessor-based particulate monitor suitable for

ambient, environmental, and indoor air quality investigations. Highly sensitive, this

monitor uses light scattering to measure particle concentration and provide immediate

real-time determinations and data recordings of airborne particle concentration in

milligrams per cubic meter ( mg/ m3) . Interchangeable size-selective sampling heads allow

PM10, PM2.5, PM1.0, or TSP monitoring. The unique aerodynamic particle sizing and optional

47-mm in-line filter holder loaded with an appropriate filter can provide concurrent

gravimetric sampling. Sampling data can be downloaded to and stored on a PC for analysis and

report generation using DustComm Pro Software ( included) .

Fast, easy setup
Highly sensitive and accurate
0.001 to 20.0 mg/ m3 for particles 0.1 to 100 µ m
Optional 0.01 to 200 mg/ m3 range available
Accuracy is ± 10% to NIOSH Method 0500 using SAE fine test dust

Internal air sample pump for 4.0 L/ min flows ( pump has a variable flow rate designed for use
at 4.0 L/ min to achieve proper size selection.)

Internal temperature compensation for ambient use

Unique aerodynamic particle-sizing real-time sensor
Use optional EPA FRM-style filter holder for gravimetric reference

High correlation to EPA PM10 methods and TEOM®

Up to 24-hour operation on one battery charge
Continuous monitoring with AC adapter

Immediate display and data storage
Rugged water-tight carry case
Audible alarm siren

Store up to 15 months of data
RS232 digital output

Easy-to-use DustComm Pro data analysis and reporting software included

Large, easy-to-read display

Portable and compact
6 x 14 x 10 inches ( 15.2 x 35.6 x 25.4 cm)
12 pounds ( 5.4 kg)

Interchangeable size-selective sampling heads for EPA parameters
PM10, PM2.5, PM1.0, and TSP

Real-time clock and data display

RFI/ EMI shielded; CE marked

EPAM 5000 Features
User-programmable start and stop time for unattended data collection

On-screen user-selectable sampling parameters retained in memory for quick, easy deployment

when sampling parameters remain unchanged

Wireless data transmission option transmits data up to 10 miles

Improved DustComm Pro PC Software provides:
Greater flexibility in graphical reports — create and label in new " draw and paint" program
Basic trend analysis
Live data feed and logging from wireless data transmission

Interfaces with the VDM-7500 wireless video exposure dust monitoring system

EPAM-5000 Applications :
Quantifying off-site particulate migration
Surveying for PM2.5 and PM10
Monitoring dust generation during drilling and excavation
Evaluating dust suppression and engineering controls
Locating and identifying " hot spots"
Emergency response and fugitive emissions compliance
Determining level of respiratory protection
Survey of workplace for OSHA/ EPA compliance
Evaluating worker exposure to airborne contaminants
Dust collector/ ventilation system checks
Monitoring lung-damaging particles in factories and buildings
Complementary instrument for all EPA and OSHA personal and ambient particulate air sampling

procedures
The EPAM-5000 Advantage
One compact instrument provides real-time data and gravimetric samples for analysis

Immediate display and datalogging of particulate concentrations

Data provides a graphic profile of PM sample

Added-value survey sampler for saturation monitoring studies

Allows immediate and permanent documentation

Reduces the number of manual gravimetric test as well as labor and analysis costs

Easy setup and operation — ready in 15 seconds

Performance Profile :
Sensing Range 0.001 to 20 mg/ m3
0.01 to 200 mg/ m3 ( optional)
Particle Size Range 0.1 to 100 µ m
Precision ± 0.003 mg/ m3 ( 3 µ g/ m3)
Accuracy ± 10% to NIOSH Method 0500 using SAE fine test dust
Sampling Flow Rate 4.0 L/ min with variable adjustment
Filter Cassette Holder
( optional accessory) 47 mm
Alarm Output 90 db at 3 ft
Analog Output 0 to 4 vdc
Recording Time 1 sec to 15 mos
Sampling Rate 1 sec, 10 sec, 1 min, and 30 min
Data Storage 21, 600 data points
Security Code 4-digit combinations
Memory and Time Storage > 10 years
Data Display Concentration in mg/ m3 and TWA, MAX, MIN, STEL, DATE, and Time
Digital Output RS232
Operating Temperature -10 to 50 C
Storage Temperature -20 to 60 C
Power Rechargeable lead-acid battery
Operating Time > 24 hrs
Charging Time 10 to 12 hrs
Dimensions ( case) 6 x 14 x 10 in
( 15.2 x 35.6 x 25.4 cm)
Weight 12 lbs ( 5.4 kg)