Welcome to Indomonster.com
Sign In | Sign Up
PRO TEKNIK
PRO-TEKNIK
Priority Member Indomonster Priority 13rd Year
PRO-TEKNIK
http://indomonster.com/pro-teknik/
Contact Information
Name:
Mr. Romeo Sinaga
[Marketing]
E-mail:

Homepage:
Instant Messaging:
Y!: pro.teknik 
Phone Number:
Phone number of Mr. Romeo Sinaga at Jakarta Timur
Mobile Number:
Mobile number of Mr. Romeo Sinaga at Jakarta Timur
Fax Number:
Fax number of Mr. Romeo Sinaga at Jakarta Timur
Address:
JL. Taruna dalam VII No.56 , Pulogadung, Indonesia
Jakarta Timur 13260, Jakarta
Indonesia
Valid Address
PRO-TEKNIK INDONESIA, Supplier & Trading CALIBER INTERNATIONAL PRODUCT
Average User Review

There is no review for this company

Write a review
Language :

Products Catalog

Jual IKA C 200 Calorimeter System, Hub. Bp. Sinaga, Hp. 0815 1311 6206, tlpn/ fax: 021 470 4719, email: pro.teknik@ yahoo.co.id
Pricemahal
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
Pack. & Deliverystandard
OriginGermany

Specification

IKA C 200 Calorimeter System

One system, four methods— manual, isoperibolic, dynamic, and time controlled
Automatic sample ignition
Compact modular design
Highly operator maintenance friendly
This easy-to-use calorimeter system allows you to accurately determine the Gross Calorific Value ( GCV) of samples in either liquid or solid state. The digital display provides simple programming and method selection. Unit is suitable for low through-put laboratories, teaching and training, e.g. technical schools, universities, and for industrial laboratories with less need for analyses.

Choose from four different methods depending on your requirements: manual, time controlled, isoperibolic, or dynamic. In the manual ( learning) method the user triggers ignition and the end of the measurement. The temperature changes are recorded at minute intervals. All calculations are manual.

In the other operating modes, ignition and calculation of GCV are automatic. The GCV is shown on the display. Acid correction of the GCV and caluculation of the heat values are performed manually. Requires manual filling of water and oxygen. Calorimeter is validated according to:

DIN 51900

ISO 1928

ASTM D240

ASTM D4809

ASTM D5865

ASTM D1989

ASTM D5468

ASTM E711

What' s Included:
measuring cell, decomposition vessel, oxygen filling station, and consumables for calibration and installation.

Specifications
Range 40, 000 joules
Interface 1 x serial ( RS232) ; 1 x parallel ( Centronics)
Measuring time isoperibol - up to 17 min; dynamic - up to 8 min; manual ( isoperibol) - up to 17 min; time-controlled - up to 14 min
Dimensions 15-3/ 4" W x 15-3/ 4" H x 15-3/ 4" D ( 400 x 400 x 400 mm)
Reproducibility 0.1% RSD ( relative standard deviation)
Power watts 120
Manufacturer number 8802501
Model C200
Brand IKA