Free Member 
Language :
MEMMERT, HIRAYAMA, ALL AMERICAN, HACH, ORION, EUTECH, LUTRON, HANNA, FUNKE GERBER, OLYMPUS, DENVER, CORNING
Contact Information
Name:
Mr. Marketing Presisi [Marketing]
E-mail:
Phone Number:
Phone number of Mr. Marketing Presisi at Jakarta, BEKASI
Mobile Number:
Mobile number of Mr. Marketing Presisi at Jakarta, BEKASI
Fax Number:
Fax number of Mr. Marketing Presisi at Jakarta, BEKASI
Address:
Jl.Pulo Ribung Raya no 36 Bekasi
" Untuk info harga & stock " dapat email : mksjakarta@ cbn.net.id
Average User Review

There is no review for this company

Write a review

Sell

Orion 4-Star Plus Benchtop pH/ Conductivity Meter
PriceBERSAING
Quantity Order:
Payment MethodCashier Order
Quantityper unit
Pack. & Deliveryper unit
OriginUnited States
Specifications:
pH :
Readout/ Resolution : -2.000 to 19.999 or 0 to 14 in aqueous solutions / 0.1, 0.01, 0.001
Relative Accuracy : ± 0.002
SMART STABILITYâ„¢ and SMART AVERAGINGâ„¢ : Resolution dependent / automatic
mV :
Range – mV / RmV : ± 1999.9
ORP : EH autocalibration to standard hydrogen electrode
Resolution : 0.1
Relative Accuracy : ± 0.2 mV or 0.05% , whichever is greater
CONDUCTIVITY :
Range : 0.000 to 3000 mS/ cm, auto resolution with cell constant dependence
Resolution : 4 signi cant digits down to 0.001 µ S/ cm, cell constant dependent
Relative Accuracy : 0.5% ± 1 digit or 0.01 µ S/ cm, whichever is greater
Cell Constant : 0.001 to 199.9
Cell Compatibility : 2 Cell, 4 Cell, Planar Cell
SMART STABILITYâ„¢ and SMART AVERAGINGâ„¢ : Resolution dependent / automatic
DirectCalâ„¢ / AUTO-CALâ„¢ : 1 to 5 points / 1 to 3 points
RESISTIVITY :
Range / Resolution : 0.0001 to 100 Megohm / Auto resolution
Relative Accuracy : 0.5 % ± 1 digit
SALINITY :
Range / Resolution : 0.01 to 80.0 ppt NaCl equivalent, 0.01 to 42ppt practical salinity / 0.01
Relative Accuracy : ± 0.1 ± 1 digit
TDS :
Range / Resolution : 0 to 19999 / 1 mg/ L
Relative Accuracy : ± 0.5 % ± 1 digit
Adjustable TDS Factor : 0.00 to 10.00
TEMPERATURE :
Range / Resolution : -5 to 105 ° C / 0.1 up to 99.9 ° C, 1.0 over 99.9 ° C
Relative Accuracy : ± 0.1 ° C
Temperature Compensation : Cond ( nLF, linear 0.0 to 10.0% / ° C) ; pH ( auto/ manual)
Display : Custom backlit LCD, for easy viewing
INPUTS / OUTPUTS :
Sensor Inputs : Conductivity-miniDIN - Locking; ATC-miniDIN-Locking; pH - BNC; Reference-Pin tip; Stirrer-Phono-jack
Solid State pH Sensor : ISFET
Communications : Bi-directional RS232 - Stereo jack, optional USB interface Cable
SPECIAL GLP SOFTWARE FEATURES :
# Of Data Logging Points : 750 points by time, stability or manual read with time/ date stamp
Calibration Log : Last 10 Calibrations
Advanced Self-test and Diagnostics : YES
GLP Electrode Veri cation : YES
Password Protection : YES