Specification :
Functions
l Semiautomatic two point calibration: Automated calibration of transducer zero offset and/ or material velocity
l Flaw Locating Live display Sound-path, Projection ( surface distance) , Depth, Amplitude,
l Flaw sizing: Automatic flaw sizing using AVG/ AVG or DAC, speeds reporting of defect acceptance or rejection.
l Digital Readout and Trig. Function: Thickness/ Depth can be displayed in digital readout when using a normal probe and Peam path, Surface Distance and Depth are directly displayed when angle probe is in use.
l Both the DAC and the AVG method of amplitude evaluation are available.
l TVG( Time Varied Gain) .
l AWS D1.1.
l Curved Surface Correction feature
l Crack Height Measure function
l Weld figure feature
l Magnify gate spreading of the gate range over the entire screen width
l Video Recording and play
l Auto-gain function
l Envelope: Simultaneous display of live A-scan at 60 Hz update rate and envelope of A-scan display
l Peak Hold: Compare frozen peak waveforms to live A-Scans to easily interpret test results.
l A Scan Freeze Display freeze holds waveform and sound path data
l B Scan display feature
Specifications
l Range: 0 to 9999 mm, at steel velocity
l Material Velocity: 1000 to 9999m/ s
l Display Delay: -20 to 3400 µ s
l Probe Delay/ Zero Offset : 0 to 99.99µ s
l Sensitivity: 110 dB max in selectable resolution 0.1, 1.0, 2.0, 6.0 dB and locked.
l Test Modes: Pulse echo, dual element and thru-transmission
l Pulser: Tunable Square Wave Pulser
l Pulse Repetition Frequency ranges from 10 Hz to 1000 Hz
l Pulse Energy: Low, Medium and High
l Damping: 100, 200, 400 ohms
l Bandwidth ( amplifier bandpass ) : 0.5 to 15 MHz
l Gate Monitors: Two independent gates controllable over entire sweep range
l Rectification: Positive halfwave, negative halfwave, fullwave, RF
l System Linearity: Horizontal: + / -0.2% FSW, Vertical: 0.25% FSH, Amplifier Accuracy + / -1 dB.
l Reject ( suppression) : 0 to 80% full screen height
l Units: Inch or millimeter
l Transducer Connections: BNC or LEMO
l Power Requirements: AC Mains 100-240 VAC, 50-60 Hz
l Operating Temperature: -10 to 50
l Storage Temperature: -30 to 50