Welcome to
Indomonster Priority17th Year
The HD2108.1 and HD2108.2 with one input and the HD2128.1 and HD2128.2 with two inputs are portable instruments with a large LCD display. They measure the temperature using immersion, penetration air or contact probes. The sensor may be a thermocouple of type K, J, T, N, R, S, B or E. The HD2108.2 and HD2128.2 instruments are dataloggers. The HD2108.1 memorizes up to 76, 000 samples, the HD2128.2 up to 38, 000 pairs of values. These data can be transferred from the instrument connected to a PC via the multi-standard RS232C serial port and USB 2.0. The storing interval, printing, and baud rate can be configured using the menu. All the models are fitted with an RS232C serial port and can transfer the acquired measurements in real time to a PC or to a portable printer. The Max, Min and Avg function calculate the maximum, minimum or average values. Other functions include: the relative measurement REL, the HOLD function, and the automatic turning off that can also be disabled. The HD2128.1 and HD2128.2 calculate the A-B difference of the temperatures captured by the two input channels. The instruments have IP67 protection degree. INSTRUMENT TECHNICAL CHARACTERISTICS Instrument Dimensions ( Length x Width x Height) 185x90x40mm Weight 470g ( complete with batteries) Materials ABS, rubber Display 2x41D2 digits plus symbols Visible area: 52x42mm Operating conditions Operating temperature -5⦠50° C Warehouse temperature -25⦠65° C Working relative humidity 0⦠90% RH without condensation Protection degree IP67 Power Batteries 4 1.5V type AA batteries Autonomy 200 hours with 1800mAh alkaline batteries Power absorbed with instrument off 20¼ A Mains Output mains adapter 9Vdc / 250mA Measuring unit ° C - ° F - ° K - mV - mV* C Security of memorized data Unlimited, independent of battery charge conditions Time Date and time Schedule in real time Accuracy 1min/ month max departure Measured values storage Type - model HD2108.2 2000 pages containing 38 samples each Total of 76, 000 samples Type - model HD2128.2 2000 pages containing 19 samples each 38, 000 pairs of samples Storage interval 1s⦠3600s ( 1hour) Serial interface RS232C Type RS232C electrically isolated Baud rate Can be set from 1200 to 38400 baud Data bit 8 Parity None Stop bit 1 Flow Control Xon/ Xoff Serial cable length Max 15m Immediate print interval 1s⦠3600s ( 1hour) USB interface - model HD2108.2 and HD2128.2 Type 1.1 - 2.0 electrically isolated Connections Input for probes 2-pole female polarized standard miniature connector Serial interface and USB 8-pole MiniDin connector Mains adapter 2-pole connector ( positive at centre) Measurement of temperature by Instrument TC measurement range: K -200⦠+ 1370° C TC measurement range: J -100⦠+ 750° C TC measurement range: T -200⦠+ 400° C TC measurement range: N -200⦠+ 1300° C TC measurement range: R + 200⦠+ 1480° C TC measurement range: S + 200⦠+ 1480° C TC measurement range: B + 200⦠+ 1800° C TC measurement range: E -200⦠+ 750° C Resolution 0.05° C up to 199.95° C 0.1° C from 200.0° C to the full scale Instrument precision Thermocouple K ± 0.1° C up to 600° C ± 0.2° C over 600° C Thermocouple J ± 0.05° C up to 400° C ± 0.1° C over 400° C Thermocouple T ± 0.1° C Thermocouple N ± 0.1° C up to 600° C ± 0.2° C over 600° C Thermocouple R ± 0.25° C Thermocouple S ± 0.3° C Thermocouple B ± 0.35° C Thermocouple E ± 0.1° C up to 300° C ± 0.15° C over 300° C The accuracy only refers to the instrument. Error due to the thermocouple or to the cold junction reference sensor is not included. Temperature drift @ 20° C 0.02% / ° C Drift after 1 year 0.1° C/ year