Specification :
DESCRIPTION
On-site hydrogen generator in an integrated, automated, site-ready enclosure.
Load Following operation automatically adjusts output to match demand.
ELECTROLYTE
Proton Exchange Membrane ( PEM) - caustic-free
HYDROGEN PRODUCTION
Net Production Rate:
Nm3/ hr @ 0° C, 1 bar 0.53 Nm3/ hr
SCF/ hr @ 70° F, 1 atm 20 SCF/ hr
SLPM @ 70° F, 1 atm 9.4 SLPM
kg per 24 hours 1.14 kg/ 24hr
Delivery Pressure - Nominal 13.8 barg ( 200 PSIG)
Power Consumed per 6.7 kWh/ Nm3
Volume of H2 Gas Produced 17.6 kWh/ 100 ft3
Purity ( Concentration of Impurities) ( 99.9995% ) Water Vapor < 5 PPM, -65° C ( -85° F) Dewpoint, N2 < 2
PPM, O2 < 1 PPM, All Others Undetectable
Turndown Range 0 to 100% net product delivery
Upgradeability N/ A
DI WATER REQUIREMENT
Rate at Max Consumption Rate 0.235 L/ hr ( 0.065 gal/ hr) 0.47 L/ hr ( 0.13 gal/ hr) 0.94 L/ hr ( 0.25 gal/ hr)
Temperature 5° C to 35° C ( 41° F to 95° F)
Pressure 1.5 to 4 barg ( 21.8 to 58.0 PSIG)
Input Water Quality ASTM Type II Deionized Water required, 1 megOhm-cm)
ASTM Type I Deionized Water preferred, 10 megOhm-cm
HEAT LOAD AND COOLANT REQUIREMENT
Cooling Air-Cooled
Heat Load from System 2.2 kW Max.
Coolant Ambient Air, 5° C to 40° C ( 41° F to 104° F)
ELECTRICAL SPECIFICATIONS
Recommended Breaker Rating 8 kVA
Electrical Specification 205 to 240 VAC, single phase, 50 or 60 Hz
INTERFACE CONNECTIONS * Consult Installation Manual for details*
H2 Product Port 1/ 4ó CPITM compression tube fitting, SS
H2/ H2O Vent Port 1/ 2ó CPITM compression tube fitting, SS
DI Water Port 1/ 4ó tube push-to-lock, polypropylene
Calibration-Gas Port N/ A
Coolant Supply Port N/ A
Coolant Return Port N/ A
Drain Port 1/ 4ó tube push-to-lock, polypropylene
Electrical Connect to on-board circuit breaker
Communications RS 232, Ethernet
CONTROL SYSTEMS
Standard Features Fully automated, push button start/ stop. E-stop. On-board H2 Leak detection.
Automatic fault detection and system depressurization.
Remote Alarm Form C relay, 2A/ 30VDC rated switching
Remote Shutdown Circuit breaker shunt trip
ENCLOSURE CHARACTERISTICS
Dimensions, W x D x H( Product / Est. Shipping) 31ó x 38ó x 42ó ( 79 cm x 97 cm x 107 cm) / 38ó x 45ó x 52" ( 97 cm x 114 cm x 132 cm)
Weight ( Product / Est. Shipping) 475 lbs ( 216 kg) / 650 lbs ( 295 kg)
Rating IP22
ENVIRONMENTAL CONSIDERATIONS * Do Not Freeze*
Standard Siting Location Indoor, level – 1° , 0 to 90% RH non-condensing, Non-hazardous/ non-classified
environment.
Storage/ Transport Temperature 5° C to 60° C ( 41° F to 140° F)
Ambient Temperature Range 5° C to 40° C ( 41° F to 104° F)
Altitude Range - Sea Level to: 1520 m ( 5000 ft)
Ventilation Proper ventilation must be provided from a non-hazardous area, at a rate in
accordance with IEC60079-10, Zone 2 NE
SAFETY AND REGULATORY CONFORMITY
Maximum On-board H2 Inventory at 0.016 Nm3
Full Production 0.6 SCF
0.0014 kg
Cabinet Ventilation with Environment NFPA 69 and EN 1127-1, Clause 6.2.
Vent fan draws fresh air up to 28 Nm3/ min ( 1000 ft3/ min)
Noise dB( A) at 1 Meter < 70
Approvals cTUVus ( UL and CSA equivalent) , CE ( PED, ATEX, LVD, Mach. Dir., EMC) , NYFD Approval