    Multiparameter Patient Monitor MD908

    Quantity Order:
    Origin:
    China
    Payment Method:
    L/C

    Specification :

    Meditech MD908 is a compact Multi-parameter Patient Monitor with color TFT display. It has standard parameters as ECG, NIBP and SPO2, and optional parameters as RESP, 2-TEMP, 2-IBP, ETCO2, Network, Thermal Printer, Pacing Maker.
    l ECG
    Lead type : 5-lead
    Input : RA; LA ; RL ; LL ; V
    Sweep speed : 12.5mm/ s, 25mm/ s, 50mm/ s
    Accuracy : 1¾ 1bpm or 1¾ 1% , which is greater
    Protection : Withstand 4000VAC/ 50Hz voltage in isolation against electrosurgical and defibrillation
    S-T detection : YES, Arrhythmia analysis : YES
    Alarm : YES, audible and visual alarm, alarm events recallable NIBP
    Method : Oscillometry
    Operation modes : Manual/ Automatic/ STAT
    Measurement unit : mmHg / KPa selectable
    Measurement types : Systolic, Diastolic, Mean
    Over-pressure protection : YES
    l SPO2
    Measurement range : 0-100%
    Accuracy : 2digit( 70~ 100% )
    0~ 69% unspecified
    l Standard Configuration
    ECG, NIBP, SPO2
    Optional
    RESP, 2-TEMP, 2-IBP, ETCO2, Network, Thermal Printer, Pacing Maker

    ECG
    Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL, V)
    Lead selection I, II, III, avR, avL, avF, V,
    Waveform 2 ch
    Lead mode 3 Leads ( R, L, F or RA, LA, LL)
    Lead selection I, II, III,
    Waveform 1 ch
    Gain ´ 2.5mm/ mV, ´ 5.0mm/ mV, ´ 10mm/ mV, ´ 20mm/ mV
    HR and Alarm
    Range
    Adult 15 ~ 300 bpm
    Neo/ Ped 15 ~ 350 bpm
    Accuracy ± 1% or ± 1bpm, which great
    Resolution 1 bpm
    Sensitivity > 200 uV P-P
    Differential Input Impedance > 5 M©
    CMRR
    Monitor > 105 dB
    Operation > 105 dB
    Diagnosis > 85 dB
    Electrode offset potential ± 300mV
    Leakage Current < 10 uA
    Baseline Recovery 2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
    Alarm Available
    Review Available

    RESPARATION
    Method Impedance between R-F( RA-LL)
    Differential Input Impedance > 2.5 M©
    Measuring Impedance Range: 0.3~ 5.0©
    Base line Impedance Range: 0 – 2.5 K©
    Bandwidth 0.3 ~ 2.5 Hz
    Resp. Rate
    Measuring and Alarm Range Adult 0 ~ 120 rpm
    Neo/ Ped 0 ~ 150 rpm
    Resolution 1 rpm
    Accuracy ± 2 rpm
    Apean Alarm 10 ~ 40 S

    NIBP
    Method Oscillometric
    Mode Manual, Auto, STAT
    Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 Min
    Measuring Period in STAT Mode 5 Min
    Pulse Rate Range 40 ~ 240 bpm
    Alarm Type SYS, DIA, MEAN
    Measuring and alarm Range Adult Mode
    SYS 40 ~ 270 mmHg
    DIA 10 ~ 215 mmHg
    MEAN 20 ~ 235 mmHg
    Pediatric Mode
    SYS 40 ~ 200 mmHg
    DIA 10 ~ 150 mmHg
    MEAN 20 ~ 165 mmHg
    Neonatal Mode
    SYS 40 ~ 135 mmHg
    DIA 10 ~ 100 mmHg
    MEAN 20 ~ 110 mmHg
    Resolution
    Pressure 1mmHg

    Accuracy Pressure
    Maximum Mean error ± 5mmHg
    Maximum Standard deviation ± 8mmHg
    Overpressure Protection
    Adult Mode 297± 3 mmHg
    Pediatric Mode 240± 3 mmHg
    Neonatal Mode 147± 3 mmHg

    SpO2
    Measuring Range 0 ~ 100 %
    Alarm Range 0 ~ 100 %
    Resolution 1 %
    Accuracy 70% ~ 100% ± 2 %
    0% ~ 69% unspecified
    Actualization interval about 1Sec.
    Alarm Delay 10 Sec.
    Pulse Rate
    Measuring and Alarm Range
    0~ 254bpm
    Resolution 1bpm
    Accuracy ± 2bpm
    Alarm Delay 10 Sec.

    MASIMO Specification:
    Range
    Saturation( % SpO2) 1% ~ 100%
    Pulse Rate( bmp) 25~ 240
    Accuracy
    Saturation( % SpO2)
    During No Motion Conditions*
    Adults 70%
    100 ± 2digits
    0% -69% unspecified
    Neonates 70%
    100% ± 2digits
    Saturation( % SpO2)
    During Motion Conditions* *
    Adults 70%
    100 ± 3digits
    0% -69% unspecified
    Neonates 70%
    100% ± 3digits
    Pulse( bpm)
    During No Motion Condition 25 to 240 ± 3digits
    Pulse( bpm)
    During Motion Condition 25 to 240 ± 5digits
    Resolution
    Saturation( % SpO2) 1%

    TEMPERATURE
    Channel 2
    Measuring and Alarm Range 0 ~ 50 ° C
    Resolution 0.1° C
    Accuracy ± 0.1° C
    Actualization interval about 1 Sec.
    Average Time Constant < 10 Sec.

    EtCO2 , IBP , Recorder