    HACH 2100Q Portable Turbidimeter

    Price:
    CALL PRICE
    Quantity Order:
    Origin:
    United States
    Payment Method:
    Telegraphic Transfer (T/T)
    Pack. & Delivery:
    unit
    2100Q Portable Turbidimeter

    Meets EPA Method 180.1
    • Single-standard RapidCalTM calibration offers the simplest solution for low-level measurements.
    • Single-step verification and on-screen assisted calibration eliminates the need to reference complicated manuals.
    • Optional USB+ Power Module ( LZV813) enables simple data transfer. All data is easily downloaded to any computer, providing superior data integrity and availability.
    • Exclusive algorithm in the Rapidly Settling TurbidityTM mode provides accurate, repeatable measurements for rapidly settling, difficult-to-measure samples while eliminating the need for redundant measurements and estimating.

    Hach portable turbidimeters are supplied with four AA alkaline batteries, a carrying case with insert, StablCal primary calibration standards in 1" sealed vials ( 20, 100, 800 NTU) , a 10 NTU primary verification standard, 6 sample cells with screw-tops, instrument manual ( printed and on CD-ROM) , quick start guide, silicone oil and oiling cloth.

    Method Range EDL Proc. Approved Reagent Ordering
    USEPA Method 180.1 0 to 1000 NTU .01 NTU on lowest range

    2100Q Portable Turbidimeter

    Specifications

    Measurement Method Ratio turbidimetric determination using a primary nephelometric light
    scatter signal ( 90° ) to the transmitted light scatter signal
    Regulatory Meets EPA Method 180.1
    Lamp Source Tungsten filament lamp
    Range 0-1000 NTU
    Accuracy ± 2% of reading plus stray light from 0-1000 NTU
    Repeatability ± 1% of reading or 0.01 NTU, whichever is greater
    Resolution 0.01 NTU on lowest range
    Stray Light = 0.02 NTU
    Signal Averaging Selectable on or off
    Detector Silicon Photodiode
    Reading Modes Normal ( Push to Read)
    Signal Averaging
    Rapidly Settling Turbidity( TM)
    Calibration Options Single step RapidCal( TM) for low-level regulatory reporting from 0-40 NTU
    Full range calibration from 0-1000 NTU
    Calibration to degrees of turbidity
    Calibration Logger Records the last 25 successful calibrations
    Verification Logger Logs the last 250 successful verifications
    Data Logger 500 records
    Power Requirement AC 100-240 V, 50/ 60 Hz ( with optional Power or USB+ Power Module)
    4 AA alkaline batteries
    Rechargeable NiMH ( with optional USB+ Power Module)
    Operating Conditions Temperature: 0 to 50 ° C ( 32 to 122 ° F)
    Relative Humidity: 0-90% at 30 ° C, 0-80% at 40 ° C, 0-70% at 50 ° C noncondensing
    Storage Conditions -40 to 60 ° C ( -40 to 140 ° F) , instrument only
    Interface Optional USB
    Sample Required 15 mL ( 0.5 oz.)
    Sample Cells Round cells, 60 x 25 mm ( 2.36 x 1 in.) , borosilicate glass with screw caps
    Dimensions 22.9 x 10.7 x 7.7 cm ( 9.0 x 4.2 x 3.0 in.)
    Weight 530 g ( 1.17 lb) without batteries
    620 g ( 1.37 lb) with four AA alkaline batteries
    Meter Enclosure Rating IP67 ( closed lid, battery and module compartment excluded)
    Protection Class Power supply: Class II
    Certification CE certified
    Warranty 1 year