    FA-400 Fully automatic chemistry analzyer

    FA-400 Fully automatic chemistry analzyer

    Quantity Order:
    Payment Method:
    Telegraphic Transfer (T/T)

    Specification :

    Features

    Random access and direct reading system

    Liquid level detection, collision protection for sample/reagent probe

    Automatic 8 channels washing station

    Interior and exterior automatic washing for sample and reagent probe

    With refrigerated reagent compartment

    Perfect self-checking function

    User-friendly software

    ISE module and barcode scanner(optional)

    Technical Specifications

    Operation: True random access

    Reading System: Direct reading system

    Assay Type: End point, Kinetic, fixed time, bi-chromatic,immunoturbidimetric, 1-2 reagent ,multistandard, reagent/serum blank, etc.

    Assay Item: 80 assays and 3 ISE (optional)

    Throughput: 400tests/hr or 550 tests/hr with ISE

    Sample Capacity: 88sample positions including standard, controls and stat, either serum cup or primary tube is available

    Sample Volume: 1-100 ul, 0.1 ul/step

    Reagent Capacity: 2*40 refrigerated reagent positions

    Reagent Volume: R1:1-400 ul, 1 ul/step; R2:1-400 ul, 1 ul/step

    Reagent Probe: With liquid level sensor, collision sensor, telfon coating and automatic washing.

    Reaction time: 0-999 seconds

    Minimum Reaction Volume: 180 ul

    Reaction Temperature: 37��plusmn;0.1��/span>

    Cuvette: High-quality UV-transmitted plastic cuvettes or quartz glass cuvettes on request

    Washing: 8 channels automatic washing system for reaction cuvette and independent washing station for each sample/reagent probe and mixer.

    Calibration: Linear and non-linear multi-point, K factor.

    Sample Dilution/Retest: sample will be diluted and retested when the result are out of range or sample is insufficent.

    Wavelength: 300nm-810nm, 10 measuring wavelengths

    Width of Band: ±2 nm

    Light Source: Long-life halogen lamp

    Absorbance Resolution: 0.0001A.

    Absorbance Accuracy:±0.0003A.

    Repeatability:d2%

    Quality Control: Levy jennings quality control program at 3 levels

    Star Test: Allowed at any time

    Report Format: multiple report formats avaiable

    Other:Tele-diagnostic, bi-direction interface to LIS system, etc.

    Language:English, French, Spanish, German, Russian, etc.

    System:Windows XP or vista

    Power Supply: AC 110V 60HZ / 220V 50HZ

    Dimensions: 100cm*85cm*75 cm

    Weight: 137kg