Specification :
Features :
=======
- Discrete, random access, fully automated
- 100 tests per hour, up to 300 tests per hour with ISE
- Up to 26 onboard chemistries and 4 ions
- Refrigerated reagent compartment
- Automatic probe cleaning, liquid level detection & collision protection
- 8 wavelengths: 340-670nm
- Automatic dilution for abnormal sample
- External bar code reader (optional)
- Bi-directional LIS interface
Technical Specifications :
=================
System Function:
- Automatic, discrete, random access
- STAT sample priority
- Throughput:
up to 100 tests/hour (without ISE), up to 300 tests/hour with ISE (4 ions)
- Measuring principles: absorbance photometry, turbidimetry, Ion Selective Electrode technology
- Methodology:
End-point, Fixed-time, Kinetic, optional ISE
- Single/dual reagent chemistries, monochromatic / bichromatic
- Linear / non-linear multipoint calibration
- Programming:
open system with user defined profiles and calculations
Reagent/Sample Handling:
- Reagent/Sample tray: 28 positions for reagents and 8 positions for samples in refrigerated compartment (4~15 )
- Reagent volume: R1: 180~450¼ul, step by 1¼ul
R2: 30~250¼l, step by 1¼ul
- Sample volume: 3~45¼ul, step by 0.5¼ul
- Reagent/Sample probe:
liquid level detection, collision protection and inventory checking
- Probe cleaning:
automatic washing both inside and outside
carry over < 0.1%
- Automatic sample dilution: pre-dilution and post-dilution dilution ratio up to 150
- Dilution vessel: disposable cuvette
External Bar Code Reader (optional):
- Used for sample and reagent programming
- Applicable to various bar code systems including Codabar ITF (Interleaved Two of Five) code128 code39 UPC/EAN Code93
- Capable to communicate with LIS in a bidirectional mode
ISE Module (optional):
- Measuring parameter: K+, Na+,Cl,Li+
- Throughput: up to 200 tests per hour
Reaction System:
- Reaction rotor: rotating tray, containing 40 cuvettes
- Cuvette: optical length 5mm
- Reaction volume: 180~500¼l
- Operating temperature: 37
- Temperature fluctuation: ± 0.1
- Independent mixing probe
Optical System:
- Light Source: Halogen-tungsten lamp
- Wavelength: 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm
- Absorption range: 0 ~3.5Abs (10mm conversion)
Control and Calibration:
- Calibration mode: linear (one point, two points and multi-points), Logit-Log 4P, Logit-Log 5P, spline, exponential, polynomial, parabola
- Control rules: west-guard multi-rule, cumulative sum check, twin plot
Operation Unit:
- Operation system: Windows 2000 Pro with SP4 or Windows XP Pro / Home
- Interface: RS-232
Working Conditions:
- Power Supply: AC200~240V, 50/60Hz, 800W
AC100~130V, 50/60Hz, 800W
- Temperature: 15-30
- Humidity: 35-85%
- Water consumption: 2.5L/hour De-ionized water
- Dimension: bench top, 690mm(W)×570 mm(D)×595 mm (H)
- Weight: 75 kg