    VICTOR 02 Thermocouple Calibrator

    VICTOR 02 Thermocouple Calibrator

    Quantity Order:
    Origin:
    China
    Pack. & Delivery:
    Carton

    Specification :

    Detail: 1.Reasonable price
    2.High quality
    3.good service

    Detail

    VICTOR 02 Thermocouple Calibrator

    - - - -
    Output | Range | Output range | Resolution | Accuracy | |
    Voltage | 100mV | -10.00 ~ 110.00mV | 0.01mV | 0.05% Setting value + 30uV | The max. output current 5mA |
    1000mV | -100.00~ 1100.0mV | 0.1mV | 0.05% Setting value 0.3mV |
    Thermocouple | R | -40~ 1760C | 1C | 0.05% Setting value 3C ( 100C) | Adopt the ITS-90 temperature |
    S | -20~ 1760C | 1C | 0.05% Setting value 2C ( > 100C) | standard ( Note 1) |
    B | 400~ 1800C | 1C | 0.05% Setting value 3C ( 400~ 600C) | |
    0.05% Setting value 2C ( > 600C) | |
    E | -200.0~ 1000.0C | 0.1C | 0.05% Setting value | |
    2C ( -100C) | |
    K | -200.0~ 1370C | 0.1C | | |
    J | -200.0~ 1200.0C | 0.1C | 0.05% Setting value | |
    T | -200.0~ 400.0C | 0.1C | | |
    N | -200.0~ 1300.0C | 0.1C | 1C ( > -100C) |
    - - - -

    - - - -
    Output | Range | Output range | Resolution | Accuracy |
    Voltage | 100mV | -10.00 ~ 110.00mV | 10uV | 0.05% Measuring value 30uV | Input Resistance 1M |
    Thermocouple | R | -40~ 1760C | 1C | 0.05% Measuring value 3C ( 100C) | xInput tesistance1M x |
    S | -20~ 1760C | 1C | 0.05% Measuring value 2C ( > 100C) | Adopt the ITS-90 |
    B | 400~ 1800C | 1C | 0.05% Measuring value 3C ( 400~ 600C) | |
    0.05% Setting value 2C ( > 600C) | temperature standard |
    E | -200.0~ 1000.0C | 0.1C | 0.05% Measuring value | ( Note 3) |
    2C ( -100C) | |
    K | -200.0~ 1370C | 0.1C | | |
    J | -200.0~ 1200.0C | 0.1C | 0.05% Measuring value | |
    T | -200.0~ 400.0C | 0.1C | | |
    N | -200.0~ 1300.0C | 0.1C | 1C ( > -100C) | |
    - - - -

    Note:

    1.Not including the accuracy of inner temperature compensatory transducer.

    The range of inner temperature compensatory transducer: -10-50C, compensatory error 0.5C.

    2.Temperature coefficient: 0.005% , range/ C( 0C-18C, 28C-50
    Model Number: VICTOR 02
    Brand Name: Local Brand
    Payment Terms: T/ T
    Minimum:
    Certification:
    Delivery Time: Within 4 weeks
    Supply Ablity:



You have [3] new inquiries.
Go to Member Menu

Home - Trade List - Product List - Inquiry List - Cooperation List - Company List
Copyright © 2024 Indomonster.com. All Rights Reserved.